Pinpoint Test
- CHECK THE KEYLESS ENTRY KEYPAD ILLUMINATION
- Ignition OFF.
- Check the keyless entry keypad illumination.
Is the keyless entry keypad illumination always on?
- Yes: GO to 8.
- No: GO to 2 .
- CHECK THE KEYLESS ENTRY KEYPAD INPUT TO THE RFA MODULE
- Using a scan tool, monitor the RFA module PIDs .
- Touch several keyless entry keypad buttons while observing the RFA module PIDs Keypd_SW_1_2, Keypd_SW_3_4, Keypd_SW_5_6, Keypd_SW_7_8 and Keypd_SW_9_0.
Do the PIDs display the correct values?
- Yes: GO to 3 .
- No: REFER to Diagnostic Routine F: The Doors Do Not Lock or Unlock Using The Keyless Entry Keypad .
- CHECK THE RFA MODULE DTCs
FROM THE SELF-TEST
- Using a scan tool, perform the RFA module self-test.
Is DTC B121A:11 present?
- Yes: GO to 4 .
- No: GO to 6.
- CHECK THE KEYLESS ENTRY KEYPAD FOR A SHORT TO GROUND
- Disconnect: Keyless Entry Keypad.
- Using a scan tool, clear the RFA module DTCs .
- Using a scan tool, perform the RFA module self-test.
Is DTC B121B:11 recorded?
- Yes: GO to 5 .
- No: INSTALL a new keyless entry keypad. REFER to Keyless Entry Keypad .
- CHECK THE KEYLESS ENTRY KEYPAD ILLUMINATION CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: RFA Module C2153D.
- Measure:
Keyless Entry Keypad Ground C500 Ground Pin Circuit Measurement / Action Pin Circuit 2 CPK28 (WH/RD) - Ground
Is the resistance greater than 10, 000 ohms?
- Yes: GO to 9.
- No: REPAIR the circuit.
- CHECK FOR RFA MODULE OUTPUT
- Using a scan tool, view RFA module PIDs .
- While active commanding the RFA module PID KEYPD_LMP_OS ON, measure:
Keyless Entry Keypad Ground C500 Ground Pin Circuit Measurement / Action Pin Circuit 2 CPK28 (WH/RD) - Ground
Is the voltage greater than 11 volts?
- Yes: INSTALL a new keyless entry keypad. REFER to Keyless Entry Keypad .
- No: GO to 7 .
- CHECK THE KEYLESS ENTRY KEYPAD ILLUMINATION CIRCUIT FOR AN OPEN
- Ignition OFF.
- Disconnect: RFA Module C2153D.
- Measure:
Keyless Entry Keypad RFA Module C500 C2153D Pin Circuit Measurement / Action Pin Circuit 2 CPK28 (WH/RD) 10 CPK28 (WH/GN)
Is the resistance less than 3 ohms?
- Yes: GO to 9.
- No: REPAIR the circuit.
- CHECK THE KEYLESS ENTRY KEYPAD ILLUMINATION CIRCUIT FOR A SHORT TO VOLTAGE
- Disconnect: RFA Module C2153D.
- Ignition ON.
- Observe the keypad illumination.
Is the keypad still illuminated?
- Yes: REPAIR the circuit.
- No: GO to 9 .
- CHECK FOR CORRECT RFA MODULE OPERATION
- Ignition OFF.
- Disconnect and inspect all RFA module connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect all RFA module connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
- Yes: CHECK OASIS for any applicable TSBs . If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new RFA module. REFER to REMOTE FUNCTION ACTUATOR (RFA) MODULE .
- No: The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.