Restraints Control Module (RCM): Installation
- Position the RCM and install the 3 RCM bolts.
- Tighten to 12 Nm (106 lb-in).
- Make sure the CPA lever is in the full release position before attempting to connect the connector.
-
NOTE: Putting the large electrical connector into the RCM on an angle can cause bad electrical connections and damage components.
Position the large RCM electrical connector into the RCM.
NOTE: Do not push the connector to the point where the lever pivots and seats itself. Light pressure is needed to get the connector into position on the RCM before using the lever to fully seat the connector. Failure to follow these instructions may result in vehicle damage, equipment damage, component damage and/or system failure.- With the large electrical connector uniformly aligned to the RCM, lightly push in until a subtle audible click is heard and slight resistance is felt.
- Connect the large electrical connector.
- Pivot the CPA toward the RCM, drawing the connector into the RCM.
- Make sure the thumb tab is engaged to the retainer on the RCM and locked in place.
- Connect the small RCM electrical connector and push the lock tab in.
- Install the floor console. REFER to CONSOLE - FRONT, FLOOR .
- Repower the SRS. REFER to Supplemental Restraint System (SRS) Depowering and Repowering - with Intelligent Access (IA) or REFER to Supplemental Restraint System (SRS) Depowering and Repowering - without Intelligent Access (IA) .
- PMI is required when installing a new RCM. Refer to the scan tool instructions to carry out PMI. REFER to PROGRAMMABLE MODULE INSTALLATION (PMI) .