Pinpoint Test
- CHECK THE CIRCUIT BETWEEN THE HVAC MODULE AND THE AUXILIARY CLIMATE CONTROL ASSEMBLY FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: Auxiliary Climate Control Assembly.
- Disconnect: HVAC Module C228B.
- Ignition ON.
- Measure:
HVAC Module Ground C228B Ground Pin Circuit Measurement / Action Pin Circuit 24 VHA38 (VT/GN) - Ground 14 VHA39 (BN/BU) - Ground 5 VHA25 (BN/VT) - Ground 11 CHA37 (WH) - Ground 10 CHA36 (GY/BN) - Ground 9 CHA35 (BU/BN) - Ground Is voltage present on any of the circuits?
- Yes: REPAIR the circuit in question.
- No : GO to 2 .
- CHECK THE CIRCUIT BETWEEN THE HVAC MODULE AND THE AUXILIARY CLIMATE CONTROL ASSEMBLY FOR A SHORT TO GROUND
- Ignition OFF.
- Measure:
HVAC Module Ground C228B Ground Pin Circuit Measurement / Action Pin Circuit 24 VHA38 (VT/GN) - Ground 14 VHA39 (BN/BU) - Ground 5 VHA25 (BN/VT) - Ground 11 CHA37 (WH) - Ground 10 CHA36 (GY/BN) - Ground 9 CHA35 (BU/BN) - Ground Are the resistances greater than 10, 000 ohms?
- Yes: GO to 3 .
- No : REPAIR the circuit in question.
- CHECK THE CIRCUIT BETWEEN THE HVAC MODULE AND THE AUXILIARY CLIMATE CONTROL ASSEMBLY FOR AN OPEN
- Disconnect: HVAC Module C228B.
- Measure:
HVAC Module Auxiliary Climate Control Assembly C228B C3198 Pin Circuit Measurement / Action Pin Circuit 24 VHA38 (VT/GN) 2 VHA25 (BN/VT) 14 VHA39 (BN/BU) 3 VHA25 (BN/VT) 5 VHA25 (BN/VT) 4 VHA25 (BN/VT) 11 CHA37 (WH) 6 VHA25 (BN/VT) 10 CHA36 (GY/BN) 7 VHA25 (BN/VT) 9 CHA35 (BU/BN) 8 VHA25 (BN/VT) HVAC Module Auxiliary Climate Control Assembly C228A C3198 Pin Circuit Measurement / Action Pin Circuit 24 LH111 (BN/WH) 5 LH111 (BN/WH) 23 RH111 (GY/BU) 1 RH111 (GY/BU) Are the resistances less than 3 ohms?
- Yes: INSTALL a new auxiliary climate control assembly. REFER to Auxiliary Climate Control Assembly . TEST the system for normal operation. If the condition returns, GO to 4 .
- No : REPAIR the circuit in question.
- CHECK FOR CORRECT HVAC MODULE OPERATION
- Ignition OFF.
- Disconnect and inspect all HVAC module connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the HVAC module connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
- Yes: CHECK OASIS for any applicable TSBs . If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new HVAC module. For EMTC, REFER to HEATING VENTILATION AIR CONDITIONING (HVAC) MODULE - EMTC or HEATING VENTILATION AIR CONDITIONING (HVAC) MODULE - DATC .
- No : The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.