Pinpoint Test
- CHECK THE HVAC MODULE FOR DTCs
- Ignition ON.
- Using a scan tool, perform the HVAC module self-test.
Is DTC B10BA:12 present?
- Yes: GO to 5 .
- No : GO to 2 .
- CHECK THE AUXILIARY BLOWER MOTOR RELAY COIL SWITCH GROUND CIRCUIT FOR A SHORT TO GROUND
- Ignition OFF.
- Disconnect: Auxiliary Blower Motor Relay.
- Disconnect: HVAC Module C228B.
- Measure:
BJB Ground Auxiliary Blower Motor Relay Socket Ground Pin Circuit Measurement / Action Pin Circuit 2 CH112 (VT/WH) - Ground Is the resistance greater than 10, 000 ohms?
- Yes: GO to 3 .
- No : REPAIR the circuit.
- CHECK THE AUXILIARY BLOWER MOTOR VOLTAGE CIRCUIT FOR A SHORT TO VOLTAGE
- CHECK THE AUXILIARY BLOWER MOTOR GROUND CIRCUIT FOR A SHORT TO GROUND
- CHECK THE AUXILIARY BLOWER MOTOR SPEED CONTROL COMMAND CIRCUIT FOR A SHORT TO VOLTAGE
- Ignition OFF.
- Disconnect: HVAC Module C228B.
- Disconnect: Auxiliary Blower Motor Speed Control.
- Ignition ON.
- Measure:
Auxiliary Blower Motor Speed Control Ground C3002 Ground Pin Circuit Measurement / Action Pin Circuit 5 VHA25 (BN/VT) - Ground Is any voltage present?
- Yes: REPAIR the circuit.
- No : GO to 6 .
- CHECK THE AUXILIARY BLOWER MOTOR SPEED CONTROL
- Install a known good auxiliary blower motor speed controller.
- Reconnect all disconnected connectors. Make sure they seat and latch correctly.
- Ignition ON.
- Operate the auxiliary blower motor.
Does the auxiliary blower motor function correctly?
- Yes: INSTALL a new auxiliary blower motor speed control. REFER to Auxiliary Blower Motor Speed Control .
- No : GO to 7 .
- CHECK FOR CORRECT HVAC MODULE OPERATION
- Ignition OFF.
- Disconnect and inspect all HVAC module connectors.
- Repair:
- corrosion (install new connector or terminals - clean module pins)
- damaged or bent pins - install new terminals/pins
- pushed-out pins - install new pins as necessary
- Reconnect the HVAC module connectors. Make sure they seat and latch correctly.
- Operate the system and determine if the concern is still present.
Is the concern still present?
- Yes: CHECK OASIS for any applicable TSBs . If a TSB exists for this concern, DISCONTINUE this test and FOLLOW TSB instructions. If no TSBs address this concern, INSTALL a new HVAC module. REFER to HEATING VENTILATION AIR CONDITIONING (HVAC) MODULE - EMTC or HEATING VENTILATION AIR CONDITIONING (HVAC) MODULE - DATC
- No : The system is operating correctly at this time. The concern may have been caused by module connections. ADDRESS the root cause of any connector or pin issues.