LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Explorer Base, 3.5 8, AWD, 6F50 >> Repair and Diagnosis >> External Pages >> Different car >> Section 273 (Handles, Locks, Latches And Entry Systems - With Intelligent Access) >> Description And Operation >> Handles, Locks, Latches and Entry Systems - With Intelligent Access (IA) >> System Operation >> Passenger Door Intelligent Access (IA)

Passenger Door Intelligent Access (IA)

WARNING: This page is about a different car, the 2013 Ford Explorer. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: The Intelligent Access (IA) feature is a programmable parameter and can be enabled/disabled with a scan tool. If the feature is disabled, the Intelligent Access (IA) feature to enter the vehicle and passive starting will be inoperative. To start the vehicle, the Intelligent Access (IA) key has to be placed in the backup slot.

The passenger door Intelligent Access (IA) feature allows the doors to be locked or unlocked without having to use the door lock cylinder or the RKE  transmitter feature. With a programmed Intelligent Access (IA) key within 1 m (3.28 ft) outside the passenger front door, touch the lock or unlock sensor on the exterior door handle. The doors lock or unlock depending upon which sensor was touched on the handle. The unlock button is located on the inside of the handle and the lock button is located on the outside face of the handle.

The passenger door Intelligent Access (IA) feature always locks or unlocks all four doors.

When the RFA  module detects that a lock or unlock sensor is touched on a front exterior door handle, it activates the low frequency antenna in the corresponding exterior front door handle. The low frequency antenna sends out a signal to the Intelligent Access (IA) key. The low frequency signal activates the Intelligent Access (IA) key and the Intelligent Access (IA) key then sends a high frequency signal back to the TPM  module. The TPM  module interprets the high frequency signal from the Intelligent Access (IA) key and sends the information to the RFA  module. If the RFA  module determines that it is a programmed key, it either unlocks all 4 doors or locks all 4 doors.