LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2012 >> Explorer Base, 3.5 8, AWD, 6F50 >> Repair and Diagnosis >> External Pages >> Different car >> Section 133 (Climate Control System - General Information And Diagnostics) >> General Procedures >> Air Conditioning (A/C) System Recovery, Evacuation and Charging >> Refrigerant System Charging Using a R-134a Manifold Gauge Set and Automatic Refrigerant Charging Meter

Refrigerant System Charging Using a R-134a Manifold Gauge Set and Automatic Refrigerant Charging Meter

WARNING: This page is about a different car, the 2013 Ford Mustang. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Ford Motor Company recommends use of a R-134a Refrigerant Management Machine to carry out charging of the refrigerant system. If a R-134a Refrigerant Management Machine is not available, refrigerant system charging may be accomplished using a separate Automatic Refrigerant Charging Meter and R-134a Manifold Gauge Set.
  1. Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to REFRIGERANT OIL ADDING .
  2. Assemble the R-134a Manifold Gauge Set, Automatic Refrigerant Charging Meter and R-134a supply tank following the Automatic Refrigerant Charging Meter operating instructions.
  3. Charge the refrigerant system following the Automatic Refrigerant Charging Meter operating instructions.
  4. If the refrigerant flow stops before the refrigerant charge is complete, start the engine, select MAX A/C operation and allow the refrigerant charge to complete.