Home >> Ford >> 2012 >> Explorer Base, 3.5 8, AWD, 6F50 >> Repair and Diagnosis >> External Pages >> Different car >> Section 113 (Sunroof - Roof Opening Panel) >> Diagnosis And Testing >> Roof Opening Panel >> Pinpoint Tests >> Pinpoint Test D: The Roof Opening Panel is Noisy During Operation >> Pinpoint Test D: The Roof Opening Panel Is Noisy During Operation

Pinpoint Test D: The Roof Opening Panel Is Noisy During Operation

WARNING: This page is about a different car, the 2013 Ford F-550 Super Duty, 2013 Ford F-450 Super Duty, 2013 Ford F-350 Super Duty, and 2013 Ford F-250 Super Duty. However, it is still accessible from the selected car via links, so may be relevant.
  1. D1 CHECK THE ROOF OPENING PANEL FOR OBSTRUCTIONS OR DAMAGE 
    • Check the roof opening panel for any obstructions and damage.
    • Are there any obstructions and/or damage? 
    • Yes  : REMOVE all obstructions. REPAIR any damage or INSTALL a new roof opening panel frame. REFER to ROOF OPENING PANEL FRAME . TEST the system for normal operation.
    • No  : GO to D2.
  2. D2 CHECK THE ROOF OPENING PANEL ALIGNMENT 
    • Check the roof opening panel during operation.
    • Is the roof opening panel loose or incorrectly aligned? 
  3. D3 CHECK THE ROOF OPENING PANEL TRACKS 
    • Open the roof.
    • Check the roof opening panel tracks for obstructions and damage.
    • Are the roof opening panel tracks OK? 
    • Yes  : GO to D4.
    • No  : REMOVE all obstructions and REPAIR any damage. TEST the system for normal operation.
  4. D4 CHECK THE ROOF OPENING PANEL SHIELD (SUNSHADE) 
    • Check the roof opening panel shield (sunshade) for correct movement.
    • Is the roof opening panel shield moving correctly? 
    • Yes  : GO to D5.
    • No  : REMOVE and REINSTALL the roof opening panel shield (sunshade). REFER to ROOF OPENING PANEL SHIELD . TEST the system for normal operation.
  5. D5 CHECK THE ROOF OPENING PANEL LIFTER ASSEMBLIES 
    • Check the roof opening panel lifter assemblies for obstructions and damage.
    • Are the roof opening panel lifter assemblies OK? 
    • Yes  : GO to D6.
    • No  : REMOVE all obstructions and REPAIR any damage. TEST the system for normal operation.
  6. D6 CHECK THE ROOF OPENING PANEL MOTOR/MODULE 
    • Remove the roof opening panel motor/module and leave the electrical connector connected.
    • Operate the roof opening panel to the full OPEN and CLOSED position.
    • Does the motor/module make excessive noise? 
    • Yes  : INSTALL a new roof opening panel motor/module. REFER to ROOF OPENING PANEL MOTOR . TEST the system for normal operation.
    • No  : REINSTALL the roof opening panel motor. REFER to ROOF OPENING PANEL MOTOR . TEST the system for normal operation. If the roof opening panel is still noisy, INSTALL a new roof opening panel frame. REFER to ROOF OPENING PANEL FRAME . If the roof opening panel is no longer noisy, the system is operating correctly. The concern may have been caused by an incorrectly installed roof opening panel motor.