DTC P1012: WASTEGATE Control Pressure Circuit Low
P1012 - WASTEGATE CONTROL PRESSURE CIRCUIT LOW
| Description: This DTC sets when the wastegate vacuum sensor reading is less than a calibrated threshold and the fault timer has exceeded the calibrated time threshold indicating a short to SIGRTN or ground. | |||
Possible Causes:
|
|||
| Diagnostic Aids: The typical minimum threshold is 0.2V and time threshold is 5 seconds. | |||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to PINPOINT TEST HN . | ||