Hardwired Inputs
The IPC requires hardwired inputs from components that are not hardwired to other modules and, therefore, are not on either HS-CAN or the MS-CAN but are required for specific IPC functions or gateway requirements. For additional information about the gateway function, REFER to Gateway Function .
The hardwired inputs are provided by components:
- Fuel pump module (primary fuel level input)
- Fuel level sensor (secondary fuel level input)
- Park detect switch (part of the floor shifter assembly)
- Washer fluid level switch