Pinpoint Test P: DTC B125D:11 Or DTC B125D:15
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- P1 CHECK THE START/STOP SWITCH PIDs
- Enter the following diagnostic mode on the scan tool: RFA Module DataLogger.
- Monitor RFA module PIDs (Crk_Fact_B1 and Crk_Fact_B2) while pressing the start/stop switch.
- Do both PIDs read YES when the switch is pressed?
- Yes : GO to P2.
- No : REFER to STEERING COLUMN SWITCHES Article to continue diagnosis of the start/stop switch.
- P2 CHECK THE START/STOP SWITCH RUN LED
- Ignition OFF.
- Disconnect: Start/Stop Switch C2195.
- Check the start/stop run LED between the start/stop switch C2195 pin 2, component side and the start/stop switch C2195 pin 1, component side.
- Does the run LED pass the diode check?
- Yes : GO to P3.
- No : INSTALL a new start/stop switch. REFER to STEERING COLUMN SWITCHES Article. CLEAR the DTCs. REPEAT the self-test.
- P3 CHECK THE START/STOP RUN LED OUTPUT CIRCUIT FOR A SHORT TO VOLTAGE
- Connect: Start/Stop Switch C2195.
- Ignition ON.
- Disconnect: RFA Module C2153d.
- Does the start/stop switch run LED continue to remain illuminated?
- Yes : REPAIR circuit CPK36 (VT/BN) for a short to voltage. CLEAR the DTCs. REPEAT the self-test.
- No : GO to P4.
- P4 CHECK THE START/STOP RUN LED OUTPUT CIRCUIT FOR AN OPEN OR SHORT TO GROUND
- Ignition OFF.
- Disconnect: Start/Stop Switch C2195.
- Measure the resistance between the start/stop switch C2195-2, circuit CPK36 (VT/BN), harness side and the RFA module 2153d-8, circuit CPK36 (VT/BN), harness side; and between the start/stop switch C2195-2, circuit CPK36 (VT/BN), harness side and ground.
- Is the resistance less than 5 ohms between the start/stop switch and the RFA module; and greater than 10, 000 ohms between the start/stop switch and ground?
- Yes : GO to P5.
- No : REPAIR the circuit for an open or short to ground. CLEAR the DTCs. REPEAT the self-test.
- P5 CHECK FOR CORRECT RFA MODULE OPERATION
- Disconnect all the RFA module connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the RFA module connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new RFA module. REFER to MULTIFUNCTION ELECTRONIC MODULE Article. TEST the system for normal operation.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.