Normal Operation
When the parking lamps are on, the Smart Junction Box (SJB) sends a Pulse Width Modulated (PWM) voltage to the hardwired dimmable illumination sources based on the input received from the instrument panel dimmer switch.
| DTC Description | Fault Trigger Conditions |
|---|---|
|
A continuous DTC that sets when the SJB has temporarily shut down the output driver. The module has temporarily disabled the backlighting output because an excessive current draw exists (such as a short to ground). The SJB cannot enable the backlighting output until the cause of the short is corrected, the DTCs have been cleared and a successful self-test is run . |
|
A continuous DTC that sets when the SJB has permanently shut down the output driver. The module has permanently disabled the backlighting output because an excessive current draw fault (such as a short to ground) has exceeded the limits that the SJB can withstand. The cause of the excessive current draw MUST be corrected before a new SJB is installed . |
|
An on-demand DTC that sets when the SJB detects an open from the backlighting output circuit. |
|
A continuous and on-demand DTC that sets when the SJB detects a short to ground from the backlighting output circuit. The DTC also sets when fuse 10 (15A) has failed or is removed |
This pinpoint test is intended to diagnose the following:
- Fuse
- Wiring, terminals or connectors
- SJB