Instrument Cluster (IC) Dealer Test Mode
To enter the IC self-diagnostic mode, begin with the ignition key in the OFF position. Press and hold the message center RESET button. Turn the key to the RUN position and hold until the display indicates ENGINEERING TEST MODE, usually within 3 to 5 seconds. Press the RESET button once to advance through each stage of the self-test. To exit the IC self-test mode, turn the ignition to the OFF position.
NOTE:
The displays listed in the table below use xxx's to represent a numeric or alpha-numeric value. The value may display the same amount of characters represented by the xxx's or there may be more/less depending on the type of display. For example: DTCS xxxx xxxx xxxx may display DTC C0100. Note that there were 12 x's in the display description but only 4 digits in the actual display.
| Message Center Display | Description |
|---|---|
| ENGINEERING TEST MODE | Initial entry display into the self-test mode. |
| SWEEP ALL GAUGES | Carries out the gauge sweep of all gauges, then displays the present gauge values. Also carries out the checksum test on ROM and EE. |
| All segments illuminated | Carries out the prove-out of all dot matrix pixels in all characters. |
| TELLTALE TEST | Illuminates all the microprocessor controlled lamps and LEDs. |
| PART NUMBER xxxx-xx | Return to normal operation of all microprocessor controlled lamps/LEDs and displays the alpha-numeric prefix and suffix of the IC part number. |
| ROM LEVEL xxxx | Displays the hexadecimal Read-Only Memory (ROM) MSB (major) and LSB (minor) level and type. If a ROM checksum fault exists, the second line displays xxx FAIL. |
| NVM ROM LEVEL xxxx | Displays the hexadecimal ROM level and type as stored in the Non-Volatile Memory (NVM). |
| NVM LEVEL xx | Displays the hexadecimal EE level. If a ROM checksum fault exists, the second line displays xxx FAIL. |
| MANUFACTURE TEST DATE xxxx | Displays hexadecimal coding of the final manufacturing test date. |
| MANUFACTURE CONFIG xx | Displays hexadecimal coding of the IC plant NVM module configuration settings. |
| VOPS CONFIG xxxxxx | Displays hexadecimal coding of vehicle options NVM module configuration settings (As-Built data). |
| DTCS xxxx xxxx xxxx or NONE | Displays a group of 3 16-bit hexadecimal format. DTCs displayed are those detected in continuous operation not during self-test. |
| SPEEDOMETER xxx.x MPH | Displays the English speed value being inputs in tenths of mph to the IC, the speedometer indicates the present filtered speed. If the High Speed Controller Area Network (HS-CAN) message is missing, the second line displays -.- MPH. If the HS-CAN message is invalid, the second line displays INVALID MPH. |
| SPEEDOMETER xxx.x km/h | Displays the metric speed value being inputs in tenths of km/h to the IC, the speedometer indicates the present filtered speed. If the HS-CAN message is missing, the second line displays -.- km/h. If the HS-CAN message is invalid, the second line displays INVALID km/h. |
| SPEEDOMETER DC xxxx | Displays corresponding gauge driver counts output for present RPM value (0-4095). |
| TACHOMETER xxxx RPM | Displays the tachometer value being input in RPM to the IC, tachometer indicates the present filtered RPM. If the HS-CAN message is missing, the second line displays -.- RPM. If the HS-CAN message is invalid, the second line displays INVALID RPM. |
| TACHOMETER DC xxxx | Displays corresponding gauge driver counts output for present RPM value (0-4095). |
| FUEL LEVEL A/D INPUT xxx | Displays the present fuel level 8 bit analog/digital input in decimal. 000-009 = short circuit. 010-254 = normal range. 255 = open. |
| FUEL LEVEL FLPS INPUT xxx | Displays the present fuel level percent status in decimal. 000-254 = normal range. 255 = open/short circuit. |
| FUEL LVL FILT FLPS INPUT xxx | Displays the present filtered fuel level percent status in decimal (used by the gauge). 000-254 = normal range. 255 = open/short circuit. |
| FUEL LEVEL DC xxxx | Displays the corresponding fuel gauge driver counts output for the filtered FLPS value (0-4095). |
| FUEL LEVEL INIT REF xxx | Displays the fuel initialization reference type used at the key on in initiation in hexadecimal, followed by the fuel level percent value of the reference in hexadecimal. |
| FUEL RAFE xx.x MPG | Displays the running average fuel economy in decimal. If the raw average fuel economy message is missing, the second line displays -.- MPG. If the raw average fuel economy message is invalid, the second line displays INVALID MPG. |
| TEMP GAUGE (-)xxx DEG C | Displays the last temperature gauge input value from the HS-CAN in degrees C, temperature gauge indicates the present filtered temperature. If the temperature message is missing, the second line displays - DEG C. If the temperature message is invalid, the second line displays INVALID DEG C. |
| TEMP GAUGE DC xxxx | Displays the corresponding gauge driver counts output for the filtered temperature value (0-4095). |
| FAIL SAFE COOL MODE xx | Displays the failsafe cooling mode message via the HS-CAN. |
| ODOMETER ROLL COUNT xxx | Displays the odometer rolling count input received via the HS-CAN, in decimal. If the temperature message is missing, the second line displays COUNT -. If the temperature message is invalid, the second line displays COUNT INVALID. |
| TRIP ODOMETER A xxxx.x | Displays the trip odometer A value stored in Random Access Memory (RAM) in miles. |
| TRIP ODOMETER B xxxx.x | Displays the trip odometer B value stored in RAM in miles. |
| BATTERY VOLTAGE xx.x V | Displays the present battery monitor reading in volts, compensated to yield voltage at the IC input pin. |
| BATTERY A/D COUNTS xxxx | Battery analog/digital counts. Displays present battery 10 bit analog/digital counts in decimal. |
| RUN/START SENSE x | RUN/START sense circuit check. B = voltage detected (circuit is high). O = no voltage detected (circuit is open). |
| DIMMING INPUT xxx | Displays the Medium Speed Controller Area Network (MS-CAN) input from the Smart Junction Box (SJB) dimming command in decimal. Displays between 0-254 (0 indicates dimming off). 255 indicates invalid data received. If the message is missing, the second line displays -. |
| DIMMING STEP xx | Display of the IC dimming step in decimal. Displays between 0-21 (0 indicates dimming off when maximum daytime brightness is detected). |
| DOOR AJAR STATUS xx | Displays the MS-CAN door ajar status received from the SJB in hexadecimal. 0 = closed and 1 = open for LH front, RH front, LH rear, RH rear, and decklid. If the door ajar message is missing, the second line displays STATUS --. |
| GEM INFO STATUS xx | Displays the MS-CAN SJB information in hexadecimal. 0 = off or disengaged and 1 = on or engaged for the headlamp on warning command, key-in-ignition warning command, park brake status, parking brake chime request, brake warning indicator request, and high beam indicator request. If the SJB message is missing, the second line displays STATUS --. |
| ABS INFO STATUS xx | Displays the HS-CAN ABS module information in hexadecimal. If the ABS message is missing, the second line displays STATUS --. |
| PCM INFO STATUS xx | Displays the HS-CAN PCM information in hexadecimal. If the PCM message is missing, the second line displays STATUS --. |
| OIL PRESSURE RA/D xxx | Displays the present ratio d oil pressure switch analog/digital input in decimal, the oil pressure warning indicator indicates the present filtered pressure. 821-1023 = switch open (oil pressure low). 615-820 = open EOL bootloader. 0-614 = switch closed (normal oil pressure). |
| MC SWITCH RA/D xxx | Displays the present message center switch input analog/digital counts in decimal. 0-48 = SETUP button pressed. 49-108 = RESET button pressed. 109-174 = INFO button pressed. 175-255 = no buttons pressed. |
| A/D PORT 0, 5, 6, 7, PL2 and PL3 RA/D xxxX | Displays 10 bit hexadecimal value of the ports analog/digital read (SBATT). |
| DIGITAL INPUTS PORT E, L and T xx | Displays 8 bit hexadecimal value of the ports readings. |
| SWEEP ALL GAUGES | Repeats the test display cycle. |