Pinpoint Test E: A Single Power Window Is Inoperative - RH Rear Window
NOTE:
Use the correct probe adapter(s) from the Flex Probe Kit when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- E1 CHECK THE RH REAR WINDOW OPERATION FROM THE LH FRONT WINDOW CONTROL SWITCH
- Ignition ON.
- Operate the RH rear window from the LH front window control switch.
- Does the RH rear window operate from the LH front window control switch?
- Yes : GO to E2.
- No : GO to E3.
- E2 CHECK CIRCUIT CPW14 (VT/WH) FOR VOLTAGE
- Ignition OFF.
- Disconnect: RH Rear Window Control Switch C801.
- Ignition ON.
-
NOTE: Set the LH window control switch to the UNLOCK position.
Measure the voltage between RH rear window control switch C801-3, circuit CPW14 (VT/WH), harness side and ground.
- Is the voltage greater than 10 volts?
- Yes : INSTALL a new RH rear window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.
- No : REPAIR the circuit. TEST the system for normal operation.
- E3 CHECK CIRCUITS CPW23 (GY) AND CPW24 (WH/VT) FOR VOLTAGE AND GROUND
- Ignition OFF.
- Disconnect: RH Rear Window Motor C803.
- Ignition ON.
- Measure the voltage between RH rear window motor C803-2, circuit CPW23 (GY), harness side and RH rear window motor C803-1, circuit CPW24 (WH/VT), harness side while operating the right rear window control switch in the DOWN then UP position.
- Is the voltage greater than 10 volts when the switch is in the DOWN position; and greater than -10 volts when the switch is in the UP position?
- Yes : INSTALL a new window regulator and motor. REFER to WINDOW REGULATOR MOTOR - REAR DOOR . TEST the system for normal operation.
- No : GO to E4.
- E4 CHECK THE RH REAR WINDOW CONTROL SWITCH
- Ignition OFF.
- Disconnect: RH Rear Window Control Switch C801.
- Carry out the window control switch component test on the RH rear window control switch.
Refer to COMPONENT TESTING article for component testing.
- Did the RH rear window control switch pass the component test?
- Yes : GO to E5.
- No : INSTALL a new RH rear window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.
- E5 CHECK CIRCUITS CPW23 (GY) AND CPW24 (WH/VT) FOR AN OPEN
- Measure the resistance between RH rear window control switch C801, harness side and RH rear window motor C803, harness side using the following chart:
RH Rear Window Control Switch Circuit RH Rear Window Motor C801-5 CPW24 (WH/VT) C803-1 C801-2 CPW23 (GY) C803-2 - Are the resistances less than 5 ohms?
- Yes : GO to E6.
- No : REPAIR the circuit. TEST the system for normal operation.
- Measure the resistance between RH rear window control switch C801, harness side and RH rear window motor C803, harness side using the following chart:
- E6 CHECK CIRCUITS CPW23 (GY) AND CPW24 (WH/VT) FOR A SHORT TO GROUND
- Measure the resistance between RH rear window control switch C801-5, circuit CPW24 (WH/VT), harness side and ground; and between RH rear window control switch C801-2, circuit CPW23 (GY), harness side and ground.
- Are the resistances greater than 10, 000 ohms?
- Yes : GO to E7.
- No : REPAIR the circuit(s) in question. TEST the system for normal operation.
- E7 CHECK CIRCUITS CPW17 (BN/GN) AND CPW18 (GY/VT) FOR AN OPEN
- Measure the resistance between LH front window control switch C504B, harness side and RH rear window control switch C801, harness side using the following chart:
LH Front Window Control Switch Circuit RH Rear Window Control Switch C504B-4 CPW17 (BN/GN) C801-1 C504B-8 CPW18 (GY/VT) C801-6 - Are the resistances less than 5 ohms?
- Yes : GO to E8.
- No : REPAIR the circuit. TEST the system for normal operation.
- Measure the resistance between LH front window control switch C504B, harness side and RH rear window control switch C801, harness side using the following chart:
- E8 CHECK CIRCUITS CPW17 (BN/GN) AND CPW18 (GY/VT) FOR A SHORT TO GROUND
- Measure the resistance between RH rear window control switch C801-1, circuit CPW17 (BN/GN), harness side and ground; and between RH rear window control switch C801-6, circuit CPW18 (GY/VT), harness side and ground.
- Are the resistances greater than 10, 000 ohms?
- Yes : INSTALL a new LH front window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.
- No : REPAIR the circuit. TEST the system for normal operation.