LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2011 >> Escape Hybrid, AWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 11 (Climate Control System - General Information And Diagnostics (Except Hybrid)) >> Diagnosis And Testing >> Climate Control System >> Component Tests >> A/C Compressor - External Leak Test

A/C Compressor - External Leak Test

WARNING: This page is about a different variant/trim than selected.
  1. Install the appropriate adapter from the A/C Flush Adapter Kit on the port of the A/C compressor, using the existing manifold retaining bolt.
  2. Connect the high and low pressure lines of a manifold gauge set or a refrigerant recovery/recycling station such as the R-134a A/C service center to the corresponding fittings on the A/C Pressure Test Adapter.
  3. Attach the center hose of a manifold gauge set to a refrigerant container standing in an upright position.
  4. Hand-rotate the compressor shaft 10 complete revolutions to distribute the oil inside the A/C compressor.
  5. Open the low pressure gauge valve, the high pressure gauge valve and the valve on the refrigerant container to allow the refrigerant vapor to flow into the A/C compressor.
  6. Using the Refrigerant Leak Detector, check for leaks at the compressor shaft.
  7. If a shaft seal or external leak is found, install a new A/C compressor. Refer to CLIMATE CONTROL article.
  8. When the leak test is complete, recover the refrigerant from the compressor.