Pinpoint Test F: The Roof Opening Panel Does Not Open Or Close In The Vent Position
NOTE:
Use the correct probe adapter(s) from the Flex Probe Kit when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- F1 CHECK THE ROOF OPENING PANEL MOTOR FOR INITIALIZATION
- Carry out the roof opening panel motor initialization procedure. Refer to ROOF OPENING PANEL MOTOR INITIALIZATION .
- Is the concern still present?
- Yes: GO to F2 .
- No: The system is operating normally at this time. The roof opening panel motor was not initialized.
- F2 CHECK THE ROOF OPENING PANEL SWITCH
- Ignition OFF.
- Disconnect: Roof Opening Panel Switch C9001.
- Carry out the roof opening panel switch component test.
Refer to appropriate SYSTEM WIRING DIAGRAMS article for component testing.
- Did the roof opening panel switch pass the component test?
- Yes: GO to F3 .
- No: INSTALL a new roof opening panel switch. REFER to ROOF OPENING PANEL CONTROL SWITCH . TEST the system for normal operation.
- F3 CHECK THE ROOF OPENING PANEL CONTROL CIRCUIT FOR AN OPEN
- Disconnect: Roof Opening Panel Motor Assembly C920.
- Measure the resistance between roof opening panel switch C9001-6, circuit CPR38 (WH/BU), harness side and roof opening panel motor assembly C920-6, circuit CPR38 (WH/BU) harness side.
- Is the resistance less than 5 ohms?
- Yes: GO to F4 .
- No: REPAIR the circuit. TEST the system for normal operation.
- F4 CHECK THE ROOF OPENING PANEL MOTOR WIRING HARNESS
- Check the roof opening panel motor wiring harness for loose pins, an open or a short between roof opening panel motor assembly C920-6, circuit CPR38, component side and the roof opening panel sliding glass motor harness connector.
- Is the roof opening panel motor wiring harness OK?
- Yes: GO to F5 .
- No: INSTALL a new roof opening panel motor wiring harness. REFER to ROOF OPENING PANEL MOTOR WIRING HARNESS . INITIALIZE the roof opening panel motor. REFER to ROOF OPENING PANEL MOTOR INITIALIZATION . TEST the system for normal operation.
- F5 CHECK THE ROOF OPENING SLIDING GLASS PANEL MOTOR FOR CORRECT OPERATION
- Disconnect all roof opening panel motor connectors.
- Check for:
- corrosion.
- bent or pushed-out pins.
- Connect all roof opening panel motor connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes: INSTALL a new roof opening sliding glass panel motor. REFER to ROOF OPENING PANEL MOTOR - SLIDING FRONT PANEL . INITIALIZE the roof opening panel motor. REFER to ROOF OPENING PANEL MOTOR INITIALIZATION . TEST the system for normal operation.
- No: The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.