Pinpoint Test B: All DIMMABLE Switch Illumination Is Inoperative
NOTE:
Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
- B1 CHECK FOR RECORDED SJB DTCs FROM THE ON-DEMAND SELF-TEST
- Use the recorded results from the SJB self-test.
- Is DTC B2A32 present?
- Yes : GO to B2 .
- No
: VERIFY the SJB
fuse 10 (15A) is OK. If OK, GO to B2
.
If not OK, REFER to the SYSTEM WIRING DIAGRAMS to identify the possible causes of the circuit short.
After the repair:
If no DTCs are present, TEST the system for normal operation.
If DTC B106E is present, CLEAR the DTCs and REPEAT the self-test (required to enable the backlighting output driver if DTC B106E is present) . TEST the system for normal operation.
If DTC B106F is present, INSTALL a new SJB . REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
- B2 BYPASS THE SJB NOTE: If the jumper wire fails, refer to the SYSTEM WIRING DIAGRAMS to identify the possible causes of the circuit short. After the repair:
If no DTCs are present, test the system for normal operation.
If DTC B106E is present, Clear the DTCs and repeat the self-test (required to enable the backlighting output driver if DTC B106E is present). Test the system for normal operation.
If DTC B106F is present, install a new SJB . Refer to MULTIFUNCTION ELECTRONIC MODULES . Test the system for normal operation.- Ignition OFF.
- Disconnect: SJB C2280b.
- Connect a fused jumper wire between the SJB C2280b-39, circuit VLN04 (VT/GY) and battery positive.
- Do the backlighting components illuminate?
- Yes : REMOVE the jumper wire. GO to B3 .
- No : REMOVE the jumper wire. REPAIR circuit VLN04 (VT/GY) for an open. CLEAR the DTCs. REPEAT the self-test.
- B3 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- damaged pins
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new SJB . REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test.