DTC P1513: - Intake Manifold Runner Control (IMRC) Stuck Closed (Bank 2)
DTC P1513: - INTAKE MANIFOLD RUNNER CONTROL (IMRC) STUCK CLOSED (BANK 2)
| Description: | This DTC is set when the vacuum actuated IMRC is commanded open, but the IMRC monitor indicates closed. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | Monitor the IMRC and IMRCM PIDs. The IMRCM state should change when the IMRC is commanded open or closed. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | - | - | GO to Pinpoint Test HU . |