Home >> Ford >> 2009 >> Taurus X SEL, FWD >> Repair and Diagnosis (Single Page) >> Body & Frame >> Sun Roof/T-Top/Convertible Top >> Sunroof - Roof Opening Panel >> Diagnostic Tests >> Roof Opening Panel >> Pinpoint Tests >> This pinpoint test is intended to diagnose the following: >> Pinpoint Test F: The Roof Opening Panel Does Not Open Or Close In Vent Position

Pinpoint Test F: The Roof Opening Panel Does Not Open Or Close In Vent Position

  1. F1 CHECK THE MOTOR/MODULE FOR INITIALIZATION 
    • Attempt to carry out the roof opening panel motor initialization procedure. Refer to Roof Opening Panel Motor Initialization .
    • Is the concern still present, or does the roof opening panel motor fail to initialize? 
    1. YES  : Go to  F2.
    2. NO  : The system is operating normally at this time. The roof opening panel motor was not initialized.
  2. F2 CHECK THE ROOF OPENING PANEL SWITCH 
    • Key in OFF position.
    • Disconnect: Roof Opening Panel Switch
    • Carry out the Roof Opening Panel Switch Component Test. Refer to appropriate COMPONENT TESTING article.
    • Is the roof opening panel switch OK? 
    1. YES  : Go to  F3.
    2. NO  : INSTALL a new roof opening panel switch. TEST the system for normal operation.
  3. F3 CHECK CIRCUIT CPR38 (WH/BU) FOR AN OPEN 
    • Measure the resistance between overhead console C930-2, circuit CPR38 (WH/BU), and roof opening panel motor/module C921-4, circuit CPR38 (WH/BU) harness side.
    • Fig 1: Measuring Resistance
      GF0045526Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR38 (WH/BU) between the roof opening panel switch socket and overhead console C930-2. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, go to  F4 .
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  4. F4 CHECK CIRCUIT CPR40 (YE/OG) FOR AN OPEN 
    • Measure the resistance between overhead console C930-3, circuit CPR40 (YE/OG), and roof opening panel motor/module C921-10, circuit CPR40 (YE/OG) harness side.
    • Fig 2: Measuring Resistance
      GF0045524Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR40 (YE/OG) between the roof opening panel switch socket and overhead console C930-3. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, go to  F5 .
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  5. F5 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR CORRECT OPERATION 
    • Disconnect all roof opening panel motor/module connectors.
    • Check for:
      • corrosion.
      • bent pins.
      • pushed-out pins.
    • Connect all roof opening panel motor/module connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    1. YES  : INSTALL a new roof opening panel motor/module. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
    2. NO  : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.