LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2009 >> Taurus X SEL, FWD >> Repair and Diagnosis (Single Page) >> Body & Frame >> Sun Roof/T-Top/Convertible Top >> Sunroof - Roof Opening Panel >> Diagnostic Tests >> Roof Opening Panel >> Pinpoint Tests >> This pinpoint test is intended to diagnose the following: >> Pinpoint Test E: The Roof Opening Panel Does Not Open Or Close

Pinpoint Test E: The Roof Opening Panel Does Not Open Or Close

  1. E1 CHECK THE MOTOR/MODULE FOR INITIALIZATION 
    1. YES  : Go to  E2.
    2. NO  : The system is operating normally at this time. The roof opening panel motor was not initialized.
  2. E2 CHECK THE POWER WINDOWS 
    • Key in ON position.
    • Verify the power windows operate.
    • Do the power windows operate? 
    1. YES  : Go to  E3.
    2. NO  : REFER to GLASS, FRAMES AND MECHANISMS article to diagnose the accessory delay relay circuit.
  3. E3 CHECK THE ROOF OPENING PANEL SWITCH 
    • Key in OFF position.
    • Disconnect: Roof Opening Panel Switch
    • Carry out the Roof Opening Panel Switch Component Test. Refer to appropriate COMPONENT TESTING article.
    • Is the roof opening panel switch OK? 
    1. YES  : Go to  E4.
    2. NO  : INSTALL a new roof opening panel switch. TEST the system for normal operation.
  4. E4 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR/MODULE - CIRCUITS CBP41 (BU) AND SBP19 (BU/RD) 
    • Key in OFF position.
    • Disconnect: Roof Opening Panel Motor/Module C921
    • Key in ON position.
    • Measure the voltage between roof opening panel motor/module C921-3, circuit CBP41 (BU) and C921-6, circuit SBP19 (BU/RD), harness side and ground.
    • Fig 1: Checking Circuit For Voltage
      GF0002086Courtesy of FORD MOTOR CO.
    • Are the voltages greater than 10 volts, but less than 16 volts? 
    1. YES  : Go to  E5.
    2. NO  : VERIFY SJB fuse 19 (25A) and fuse 41 (15A) are OK. If OK, REPAIR the circuit. TEST the system for normal operation.
  5. E5 CHECK THE ROOF OPENING PANEL GROUND - CIRCUIT GD133 (BK) 
    • Key in OFF position.
    • Measure the resistance between roof opening panel motor/module C921-1, circuit GD133 (BK), harness side and ground.
    • Fig 2: Checking Circuit For Open
      GF0002087Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : Go to  E6.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  6. E6 CHECK CIRCUIT CPR39 (VT/WH) FOR AN OPEN 
    • Measure the resistance between overhead console C930-4, circuit CPR39 (VT/WH), and roof opening panel motor/module C921-2, circuit CPR39 (VT/WH) harness side.
    • Fig 3: Measuring Resistance
      GF0045523Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR39 (VT/WH) between the roof opening panel switch socket and overhead console C930-4. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, go to  E7 .
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  7. E7 CHECK CIRCUIT CPR40 (YE/OG) FOR AN OPEN 
    • Measure the resistance between overhead console C930-3, circuit CPR40 (YE/OG), and roof opening panel motor/module C921-10, circuit CPR40 (YE/OG) harness side.
    • Fig 4: Measuring Resistance
      GF0045524Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR40 (YE/OG) between the roof opening panel switch socket and overhead console C930-3. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, go to  E8 .
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  8. E8 CHECK CIRCUIT CPR31 (VT/BN) FOR AN OPEN 
    • Measure the resistance between overhead console C930-7, circuit CPR31 (VT/BN), and roof opening panel motor/module C921-5, circuit CPR31 (VT/BN) harness side.
    • Fig 5: Measuring Resistance
      GF0045525Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR31 (VT/BN) between the roof opening panel switch socket and overhead console C930-7. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness, and TEST the system for normal operation. If the overhead console jumper harness is OK, go to  E9 .
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  9. E9 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR CORRECT OPERATION 
    • Disconnect all roof opening panel motor/module connectors.
    • Check for:
      • corrosion.
      • bent pins.
      • pushed-out pins.
    • Connect all roof opening panel motor/module connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    1. YES  : INSTALL a new roof opening panel motor/module. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
    2. NO  : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.