Removal and Installation

  1. Detach the RH scuff plate trim panel from the RH lower A-pillar trim panel.
  2. Remove the RH lower A-pillar trim panel.
  3. Remove the 2 RH lower instrument panel insulator pin-type retainers and the RH lower instrument panel insulator.
  4. Disconnect the blower motor electrical connector.
  5. Depressor the 2 retaining tabs and detach the blower motor vent tube from the heater core and evaporator core housing.
    Fig 1: Locating Retaining Tabs And Blower Motor Vent Tube
    G06064728Courtesy of FORD MOTOR CO.
  6. NOTE: The blower motor vent tube must be completely detached from the heater core and evaporator core housing to allow the blower motor to be rotated.
  7. Rotate the blower motor counterclockwise to detach it from the heater core and evaporator core housing and remove the blower motor.
  8. To install, reverse the removal procedure.