Removal and Installation
- Detach the RH scuff plate trim panel from the RH lower A-pillar trim panel.
- Remove the RH lower A-pillar trim panel.
- Remove the 2 RH lower instrument panel insulator pin-type retainers and the RH lower instrument panel insulator.
- Disconnect the blower motor speed control electrical connector.
- Remove the 2 blower motor speed control screws.
- Remove the blower motor speed control.
- To install, reverse the removal procedure.