Refrigerant System Charging Using a R-134a Refrigerant Management Machine
NOTE:
Ford Motor Company recommends use of a R-134a Refrigerant Management Machine to carry out charging of the refrigerant system. If a R-134a Refrigerant Management Machine is not available, refrigerant system charging may be accomplished using a separate Automatic Refrigerant Charging Meter and R-134a Manifold Gauge Set.
NOTE:
Leaks in refrigerant system service equipment, hoses or gauges can cause a leak that may be misinterpreted as a problem with the vehicle's refrigerant system. It is necessary to leak-test all refrigerant system service equipment, hoses and gauges on a weekly basis to verify that no leaks are present.
- Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to REFRIGERANT OIL ADDING .
- Connect a R-134a Refrigerant Management Machine to the low-side and high-side service gauge port valves following the operating instructions provided by the equipment manufacturer.
- Set the refrigerant charge amount, and charge the refrigerant system following the instructions provided by the equipment manufacturer.