Filling and bleeding procedure for use with partial drain
WARNING: This page is about a different car, the 2007 Ford Ranger. However, it is still accessible from the selected car via links, so may be relevant.
- Make sure the radiator draincock is completely closed.
- Fill the system through the degas bottle cap to 15 mm (0.590 in) above the maximum fill level.
- Install the degas bottle cap.
- Start the engine and hold at 2,500 RPM engine speed for approximately 8 minutes until the thermostat opens.
- Maintain 2,500 RPM engine speed for an additional 3 minutes.
- Increase engine speed to 4,000 RPM and hold for 5 seconds.
- Return engine speed to 2,500 RPM and hold for an additional 3 minutes.
- Stop the engine and check for leaks.
WARNING:
Do not stand in line with or near the engine cooling fan blade when revving the engine. A damaged fan can separate during operation. Failure to follow this instruction may result in serious personal injury.