P0482 - Fan 3 Control Circuit

WARNING: This page does not describe the selected car, but rather 32 other vehicles, including the 2007 Mercury Mountaineer, 2007 Mercury Monterey, 2007 Mercury Montego, 2007 Mercury Milan, and 2007 Mercury Mariner. However, it is still accessible from the selected car via links, so may be relevant.
P0482 - FAN 3 CONTROL CIRCUIT

Description:  Monitors the MFC primary circuit output from the powertrain control module (PCM). The test fails, when the MFC output is commanded on (grounded) and excessive current draw is detected on the MFC circuit; or when the MFC circuit is commanded off and voltage is not detected on the MFC circuit (the PCM expects to detect IGN START/RUN voltage through the medium speed FC relay coil to the MFC circuit).
Possible Causes: 
  • Open or short MFC circuit
  • Open IGN START/RUN circuit to the medium speed FC relay
  • Damaged medium speed FC relay
Diagnostic Aids:  When the MFCF PID reads YES, a concern is currently present. An open circuit or short to ground can only be detected when the PCM is not grounding the MFC circuit. A short to voltage can only be detected when the PCM is grounding the MFC circuit. During the key on engine off (KOEO) and key on engine running (KOER) self-test, the MFC circuit is cycled on and off. Use output test mode to command the low speed/high speed fan on. The PCM also activates the medium speed fan output.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All refer to PINPOINT TEST KF .