Pinpoint Test K: The STOPLAMPS Are On Continuously
- K1 CHECK THE STOPLAMP SWITCH INPUT
- Key in ON position.
- Enter the following diagnostic mode on the scan tool: SJB Stoplamp Switch PID.
- Monitor the SJB stoplamp switch PID.
- Does the PID indicate active with the brake pedal not applied?
Yes: GO to K2.
No: GO to K6.
- K2 CHECK THE STOPLAMP SWITCH
- Key in OFF position.
- Disconnect: Stoplamp Switch C278.
- Do the stoplamps continue to illuminate?
Yes: GO to K3.
No: INSTALL a new stoplamp switch. REFER to STOPLAMP SWITCH . TEST the system for normal operation.
- K3 CHECK THE BRAKE SHIFT INTERLOCK
- Disconnect: Selector Lever C3245.
- Do the stoplamps continue to illuminate?
Yes: GO to K4.
No: INSTALL a new selector lever. REFER to INSTALLATION . TEST the system for normal operation.
- K4 CHECK THE ABS MODULE
- Disconnect: ABS Module C135.
- Do the stoplamps continue to illuminate?
Yes: GO to K5.
No: GO to K2.
- K5 CHECK CIRCUIT 810 (RD/LG) FOR A SHORT TO VOLTAGE
- Disconnect: SJB C2280a.
- Measure the voltage between the stoplamp switch C278-1, circuit 810 (RD/LG), harness side and ground.
- Is any voltage present?
Yes: REPAIR the circuit. TEST the system for normal operation.
No: GO to K7.
- K6 CHECK STOPLAMP VOLTAGE CIRCUIT FOR A SHORT TO VOLTAGE
- Key in OFF position.
- Disconnect: SJB C2280e.
- Does a rear lamp continue to illuminate?
Yes: For all stoplamps on Montego, REPAIR circuit 1374 (TN/LB). TEST the system for normal operation.
For the high mounted stoplamp on Freestyle or Five Hundred, REPAIR circuit 1374 (TN/LB). TEST the system for normal operation.
For the LH rear stoplamp on Freestyle or Five Hundred, REPAIR circuit 1363 (WH/RD). TEST the system for normal operation.
For the RH rear stoplamp on Freestyle or Five Hundred, REPAIR circuit 1365 (GY/LB). TEST the system for normal operation.
No: GO to K7.
- K7 CHECK FOR CORRECT SJB OPERATION
- Disconnect all the SJB connectors.
- Check for:
- corrosion
- pushed-out pins
- Connect all the SJB connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
Yes: INSTALL a new SJB. REFER to REMOVAL AND INSTALLATION . TEST the system for normal operation.
No: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
- K8 CHECK FOR CORRECT ABS MODULE OPERATION
- Disconnect the ABS module connector.
- Check for:
- corrosion
- pushed-out pins
- Connect the ABS module connector and make sure it seats correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
Yes: INSTALL a new ABS module. REFER to REMOVAL AND INSTALLATION . TEST the system for normal operation.
No: The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.