Home >> Ford >> 2009 >> Flex Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 535 (Window And Glass) >> Diagnosis And Testing >> Glass, Frames and Mechanisms >> Pinpoint Tests >> Pinpoint Test C: A Single Power Window Is Inoperative - RH Front >> Pinpoint Test C: A Single Power Window Is Inoperative - RH Front

Pinpoint Test C: A Single Power Window Is Inoperative - RH Front

WARNING: This page is about a different car, the 2006 Mercury Montego, 2006 Ford Freestyle, and 2006 Ford Five Hundred. However, it is still accessible from the selected car via links, so may be relevant.
  1. C1 CHECK THE RH FRONT POWER WINDOW MOTOR 
    • Disconnect: LH Front Window Control Switch C504a and C504b.
    • Key in ON position.
    • Connect a fused jumper wire between LH front window control switch C504b-1, circuit 1505 (YE/RD), harness side and LH front window control switch C504a-5, circuit 1499 (PK/LG), harness side. Connect a second fused jumper wire between LH front window control switch C504b-5, circuit 1506 (RD/WH) and LH front window control switch C504b-4, circuit 1205 (BK). The RH front window should operate in the up direction.
      Fig 1: Checking RH Front Power Window Motor (1 Of 2)
      G04658855Courtesy of FORD MOTOR CO.
    • Connect a fused jumper wire between LH front window control switch C504b-5, circuit 1506 (RD/WH), harness side and LH front window control switch C504b-1, circuit 1499 (PK/LG), harness side. Connect a second fused jumper wire between LH front window control switch 3504b-1, circuit 1505 (YE/RD) and LH front window control switch C504b-4, circuit 1205 (BK). The RH front window should operate in the down direction.
      Fig 2: Checking RH Front Power Window Motor (2 Of 2)
      G04658856Courtesy of FORD MOTOR CO.
    • Does the RH front window operate correctly? 

    Yes:  GO to  C2.

    No:  GO to  C4.

  2. C2 CHECK CIRCUIT 170 (RD/LB) FOR VOLTAGE 
    • Key in OFF position.
    • Connect: LH Front Window Control Switch C504a and C504b.
    • Disconnect: RH Front Window Control Switch C604.
    • Key in ON position.
    • NOTE: Be sure the window lock switch is set to the unlock position.
      Fig 3: Measuring Voltage Between RH Front Window Control Switch C604-5, Circuit 170 (RD/LB), Harness Side & Ground
      G04658857Courtesy of FORD MOTOR CO.
    • Measure the voltage between RH front window control switch C604-5, circuit 170 (RD/LB), harness side and ground.
    • Is the voltage greater than 10 volts? 

    Yes:  GO to  C3.

    No:  REPAIR the circuit. TEST the system for normal operation.

  3. C3 CHECK THE LH FRONT WINDOW CONTROL SWITCH 
    • Key in OFF position.
    • Disconnect: LH Front Window Control Switch.
    • Carry out the LH front window control switch component test. Refer to COMPONENT TESTING article for component testing.
    • Did the LH front window control switch pass the component test? 

    Yes:  GO to  C4.

    No:  INSTALL a new LH front window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.

  4. C4 CHECK THE RH FRONT WINDOW CONTROL SWITCH 
    • Carry out the RH front window control switch test. Refer to COMPONENT TESTING article for component testing.
    • Did the RH front window control switch pass the component test? 

    Yes:  GO to  C5.

    No:  INSTALL a new RH front window control switch. REFER to WINDOW CONTROL SWITCH . TEST the system for normal operation.

  5. C5 CHECK CIRCUITS 1505 (YE/RD) AND 1506 (RD/WH) FOR AN OPEN 
    • Measure the resistance between RH front window control switch C604-1, circuit 1505 (YE/RD), harness side and LH front window control switch C504b-1, circuit 1505 (YE/RD), harness side.
      Fig 4: Checking Circuits 1505 (YE/RD) & 1506 (RD/WH) (1 Of 2)
      G04658858Courtesy of FORD MOTOR CO.
    • Measure the resistance between RH front window control switch C604-6, circuit 1506 (RD/WH), harness side and LH front window control switch C504b-5, circuit 1506 (RD/WH), harness side.
      Fig 5: Checking Circuits 1505 (YE/RD) & 1506 (RD/WH) (2 Of 2)
      G04658859Courtesy of FORD MOTOR CO.
    • Are the resistances less than 5 ohms? 

    Yes:  GO to  C6.

    No:  REPAIR the circuit(s). TEST the system for normal operation.

  6. C6 CHECK CIRCUIT 333 (YE/RD) AND CIRCUIT 334 (RD/YE) FOR AN OPEN 
    • Disconnect: RH Front Window Motor C608.
    • Measure the resistance between RH front window control switch C604-3, circuit 333 (YE/RD), harness side and RH front window motor C608-1, circuit 333 (YE/RD), harness side.
      Fig 6: Checking Circuit 333 (YE/RD) & Circuit 334 (RD/YE) (1 Of 2)
      G04658860Courtesy of FORD MOTOR CO.
    • Measure the resistance between RH front window control switch C604-4, circuit 334 (RD/YE), harness side and RH front window motor C608-2, circuit 334 (RD/YE), harness side.
      Fig 7: Checking Circuit 333 (YE/RD) & Circuit 334 (RD/YE) (2 Of 2)
      G04658861Courtesy of FORD MOTOR CO.
    • Are both resistances less than 5 ohms? 

    Yes:  INSTALL a new RH front window motor. REFER to GLASS, FRAMES AND MECHANISMS - EXPLODED VIEW, FRONT DOOR  and WINDOW REGULATOR AND MOTOR - FRONT DOOR . TEST the system for normal operation.

    No:  REPAIR the circuit(s). TEST the system for normal operation