Home >> Ford >> 2009 >> Flex Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 496 (HVAC Control System-General Information And Diagnostics - F250-F550 Super Duty) >> General Procedures >> Air Conditioning (A/C) System Recovery, Evacuation and Charging >> Refrigerant System Recovery >> Refrigerant System Charging Using an R-134a Service Center

Refrigerant System Charging Using an R-134a Service Center

WARNING: This page is about a different car, the 2006 Ford Pickup, 2006 Ford F550 Super Duty, 2006 Ford F450 Super Duty, and 2006 Ford Cab & Chassis. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Ford Motor Company recommends use of an A/C service center to carry out recovery, evacuation and charging of the refrigerant system. If an A/C service center is not available, refrigerant system recovery, evacuation and charging may be accomplished using a separate recovery station, vacuum pump, charging meter and manifold gauge set.
NOTE: Leaks in refrigerant system service equipment, hoses or gauges can cause a leak that may be misinterpreted as a problem with the vehicle's refrigerant system. It is necessary to leak-test all refrigerant system service equipment, hoses and gauges on a weekly basis to verify that no leaks are present.
  1. Lubricate the refrigerant system with the correct amount of clean PAG oil. For additional information, refer to REFRIGERANT OIL ADDING .
  2. Connect an R-134a A/C service center to the low-side and high-side service gauge port valves following the operating instructions provided by the equipment manufacturer.
  3. Set the refrigerant charge amount, and charge the refrigerant system following the instructions provided by the equipment manufacturer.