Home >> Ford >> 2009 >> Flex Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1683 (HVAC - Climate Control System - General Information And Diagnostics (Hybrid)) >> Diagnosis And Testing >> Climate Control System >> Pinpoint Tests >> Pinpoint Test B: DTC B1A61:11 and 15 >> Pinpoint Test B: DTC B1A61:11 And 15

Pinpoint Test B: DTC B1A61:11 And 15

WARNING: This page is about a different car, the 2010 Mercury Milan and 2010 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
  1. B1 CHECK THE SENSOR RESISTANCE 
    • Ignition OFF.
    • Disconnect: In-Vehicle Temperature/Humidity Sensor C2247.
    • Measure the resistance between the in-vehicle temperature/humidity sensor C2247-2, component side and C2247-5, component side and compare to the table below.
      TEMPERATURE RESISTANCE REFERENCE TABLE

      Ambient Temperature Resistance
      -40°C (-40°F) 862,600-942,000 ohms
      -15°C (5°F) 202,400-214,700 ohms
      0°C (32°F) 93,510-97,640 ohms
      15°C (59°F) 46,060-47,430 ohms
      25°C (77°F) 29,700-30,300 ohms
      35°C (95°F) 19,400-20,000 ohms
      60°C (140°F) 7,414-7,774 ohms
      85°C (185°F) 3,182-3,393 ohms
      Fig 1: Measuring Resistance Between In-Vehicle Temperature/Humidity Sensor C2247-2 & C2247-5, Component Side
      G06262690Courtesy of FORD MOTOR CO.
    • Is the resistance within the specified values for the temperatures? 
    • Yes:  GO to  B2.
    • No:  INSTALL a new in-vehicle temperature/humidity sensor. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  2. B2 CHECK THE SENSOR OUTPUT VOLTAGE 
    • Ignition ON.
    • Measure the voltage between in-vehicle temperature/humidity sensor C2247-2, circuit VH414 (GN/BU), harness side and C2247-5, circuit RH111 (GY/BU), harness side.
      Fig 2: Checking Sensor Output Voltage
      G06262691Courtesy of FORD MOTOR CO.
    • Is the voltage between 4.7 and 5.1 volts? 
    • Yes:  INSTALL a new in-vehicle temperature/humidity sensor. CLEAR the DTCs. REPEAT the self-test. If code returns, GO to  B8.
    • No: For DTC B1A68:15  , GO to  B3.

      For DTC B1A68:11  , GO to  B6.

  3. B3 CHECK CIRCUIT VH414 (GN/BU) FOR A SHORT TO VOLTAGE 
    • Ignition OFF.
    • Disconnect: HVAC Module - Dual Automatic Temperature Control (DATC) C2356a.
    • Disconnect: HVAC Module - DATC  C2356b.
    • Ignition ON.
    • Measure the voltage between ground and HVAC module - DATC  C2356b-21, circuit VH414 (GN/BU), harness side.
      Fig 3: Measuring Voltage Between Ground & HVAC Module DATC C2356B-21, Circuit VH414 (GN/BU), Harness Side
      G06075210Courtesy of FORD MOTOR CO.
    • Is any voltage present? 
    • Yes:  REPAIR circuit VH414 (GN/BU) for a short to voltage. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
    • No:  GO to  B4.
  4. B4 CHECK CIRCUIT VH414 (GN/BU) FOR AN OPEN 
    • Ignition OFF.
    • Measure the resistance between HVAC module - DATC  C2356b-21, circuit VH414 (GN/BU), harness side and in-vehicle temperature/humidity sensor C2247-2, circuit VH414 (GN/BU), harness side.
      Fig 4: Checking Circuit VH414 (GN/BU) For Open
      G06262693Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    • Yes:  GO to  B5.
    • No:  REPAIR circuit VH414 (GN/BU) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  5. B5 CHECK CIRCUIT RH111 (GY/BU) FOR AN OPEN 
    • Measure the resistance between HVAC module C2356a-10, circuit RH111 (GY/BU), harness side and in-vehicle temperature/humidity sensor C2247-5, circuit RH111 (GY/BU), harness side.
      Fig 5: Checking Circuit RH111 (GY/BU) For Open
      G06262694Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    • Yes:  GO to  B8.
    • No:  REPAIR circuit RH111 (GY/BU) for an open. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  6. B6 CHECK CIRCUIT VH414 (GN/BU) FOR A SHORT TO CIRCUIT RH111 (GY/BU) 
    • Ignition OFF.
    • Disconnect: HVAC Module - DATC  C2356b.
    • Measure the resistance between in-vehicle temperature/humidity sensor C2247-2, circuit VH414 (GN/BU), harness side and C2247-5, circuit RH111 (GY/BU), harness side.
      Fig 6: Checking Circuit VH414 (GN/BU) For Short To Circuit RH111 (GY/BU)
      G06262695Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms? 
    • Yes:  GO to  B7.
    • No:  REPAIR circuit VH414 (GN/BU) for a short to circuit RH111 (GY/BU). CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  7. B7 CHECK CIRCUIT VH414 (GN/BU) FOR A SHORT TO GROUND 
    • Measure the resistance between HVAC module - DATC  C2356b-21, circuit VH414 (GN/BU), harness side and ground.
      Fig 7: Measuring Resistance Between HVAC Module DATC C2356B-21, Circuit VH414 (GN/BU), Harness Side & Ground
      G06262696Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms? 
    • Yes:  GO to  B8.
    • No:  REPAIR circuit VH414 (GN/BU) for a short to ground. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.
  8. B8 CHECK THE MODULE CONNECTION 
    • Inspect the module connectors for:
      • corrosion.
      • pushed-out terminals.
      • damaged terminals.
    • Connect and correctly seat all the HVAC module connectors.
    • Clear the DTCs.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes:  INSTALL a new HVAC module. REFER to REMOVAL AND INSTALLATION . TEST the system for normal operation.
    • No:  The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. CLEAR the DTCs. REPEAT the self-test. TEST the system for normal operation.