LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2009 >> Flex Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1663 (Automatic Transaxle - AISIN Aw21) >> Diagnosis And Testing >> Diagnostic Trouble Code (DTC) Tables

Diagnostic Trouble Code (DTC) Tables

WARNING: This page is about a different car, the 2010 Mercury Milan, 2010 Lincoln MKZ, and 2010 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: This module utilizes a 5-character DTC followed by a 2-character failure type code. The failure type code provides information about specific fault conditions such as opens or shorts to ground. Continuous Memory Diagnostic Trouble Code (CMDTC) has an additional 2-character DTC status code suffix to assist in determining DTC history.
DIAGNOSTIC TROUBLE CODE (DTC) TABLE

DTC Component Description Condition Symptom Action
P0562:00 Battery System voltage low. PCM detected a voltage level below 9 volts. No engagements, no adaptive or self-learning strategy. CHECK charging system, REFER to BATTERY, MOUNTING AND CABLES .
P0563:00 Battery System voltage high. PCM detected a voltage level above 18 volts. No adaptive or self-learning strategy. CHECK charging system, REFER to BATTERY, MOUNTING AND CABLES .
P0601:00 Transmission Control Module (TCM) TCM  Read-Only Memory (ROM) error. TCM  detected an internal software concern with ROM  . No engagements, no adaptive or self-learning strategy. INSTALL a new TCM  .
P0603:00 TCM  TCM  Keep Alive Memory (KAM) error. TCM  detected an internal software concern with KAM  . No engagements, no adaptive or self-learning strategy. INSTALL a new TCM  .
P0604:00 TCM  TCM  Random Access Memory (RAM) error. TCM  detected an internal software concern with RAM  . No engagements, no adaptive or self-learning strategy. INSTALL a new TCM  .
P0706:00 Transmission Range (TR) TR  sensor range or performance error. TR  sensor signal is out of normal range. TR  sensor indicates a stuck position (D-3rd gear), no adaptive or self-learning strategy. INSTALL a new TCM  .
P0707:00 TR  Sensor TR  sensor circuit low input. TR  sensor signal is below threshold of 0.127 volt, sensor/circuit electrical malfunction. TR  sensor indicates a stuck position (D-3rd gear), no adaptive or self-learning strategy. INSTALL a new TCM  .
P0708:00 TR  Sensor TR  sensor circuit high input. TR  sensor signal is above threshold of 4.87 volts, sensor/circuit electrical malfunction. TR  sensor indicates a stuck position (D-3rd gear), no adaptive or self-learning strategy. INSTALL a new TCM  .
P0711:00 Transmission Fluid Temperature (TFT) Sensor No change in TFT  during operation. PCM has detected no TFT  change during operation. TFT  value stuck at some normal reading. TFT  indicates 80°C (176°F) at all times, no self-learning strategy, no Torque Converter Clutch (TCC) engagement. Go To PINPOINT TEST B .
P0712:00 TFT  Sensor 200°C (329°F) indicated, TFT  sensor circuit grounded. Voltage drop across TFT  sensor exceeds scale set for temperature -43°C (-45°F). TFT  indicates 80°C (176°F) at all times, no self-learning strategy, no TCC  engagement. Go To PINPOINT TEST B .
P0713:00 TFT  Sensor -43°C (-45°F) indicated, TFT  sensor circuit grounded. Voltage drop across TFT  sensor exceeds scale set for temperature -43°C (-45°F). TFT  indicates 80°C (176°F) at all times, no self-learning strategy, no TCC  engagement. Go to PINPOINT TEST B .
P0716:00 Turbine Shaft Speed (TSS) Sensor TSS  range out of performance, insufficient input from TSS  . PCM has detected a loss or noisy TSS  signal during operation. No TCC  engagements, no adaptive or self-learning strategy. Go to PINPOINT TEST D .
P0717:00 TSS  Sensor No TSS  signal. PCM has not detected a TSS  signal. No TSS  signal when Output Shaft Speed (OSS) signal present. No TCC  engagements, no adaptive or self-learning strategy. Go to PINPOINT TEST D .
P0721:00 OSS  Sensor OSS  range out of performance, insufficient input from OSS  . PCM has detected a loss or noisy OSS  signal during operation. No adaptive or self-learning strategy. Go to PINPOINT TEST C .
P0722:00 OSS  Sensor No OSS  signal. PCM has detected no OSS  signal. No engagements, no adaptive or self-learning strategy. Go to PINPOINT TEST C .
P0729:00 Transaxle 6th gear ratio. No 6th gear ratio detected by TCM  . No 6th gear, no TCC  engagements, no adaptive or self-learning strategy. Go to PINPOINT TEST A .
P0730:00 Clutch Control Solenoids or Internal Parts Gear ratio error. PCM has detected a gear ratio error. No self-learning strategy. Go to PINPOINT TEST A .
P0731:00 Solenoid or Internal Parts 1st gear ratio. No 1st gear ratio detected by TCM  . No 1st gear, no TCC  engagements, no adaptive or self-learning strategy. Go to PINPOINT TEST A .
P0732:00 Solenoid or Internal Parts 2nd gear ratio. No 2nd gear ratio detected by TCM  . No 2nd gear, no TCC  engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0733:00 Solenoid or Internal Parts 3rd gear ratio. No 3rd gear ratio detected by TCM  . No 3rd gear, no TCC  engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0734:00 Solenoid or Internal Parts 4th gear ratio. No 4th gear ratio detected by TCM  . No 4th gear, no TCC  engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0735:00 Solenoid or Internal Parts 5th gear ratio. No 5th gear ratio detected by TCM  . No 5th gear, no TCC  engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0736:00 Transaxle Reverse gear ratio. No reverse gear ratio detected by TCM  . No reverse gear, no self-learning strategy. Go To PINPOINT TEST A .
P0780:00 Solenoid or Valve Internal to Transaxle Universal shifting (stuck valve). Valve stuck. Increase rpm during shifts. Slipping or erratic shifting. GO to MAIN CONTROL VALVE BODY .
P0813:00 Reverse Lamp Module Reverse lamp short circuit. Reverse lamp short to battery. Reverse lamps inoperative. GO to AUTOMATIC TRANSAXLE/TRANSMISSION EXTERNAL CONTROLS - AISIN AW21/6F35 .
P0813:00 Reverse Lamp Module Reverse lamp open circuit. Reverse lamp short to ground. Reverse lamps always illuminated. GO to AUTOMATIC TRANSAXLE/TRANSMISSION EXTERNAL CONTROLS - AISIN AW21/6F35 .
P0817:00 TCM  /PCM Starter Circuit Starter disable circuit open or shorted to power/ground. TCM  detected a failure in the starter lock circuit, failed ON or OFF. Ignition switch is ON, TCM  and PCM communication is normal. No voltage is detected on the start lock circuit for more than 0.1 second or a continuous 12-volt output is detected for more than 0.1 second. Conditions present 2 times to set DTC. DTC is set. Warning lamp is illuminated. Go To PINPOINT TEST E .
P0819:00 Select Shift Transmission Control Circuit Select shift switch output circuit failure. The associated circuitry connected to the select shift switch or fuse, or the select shift switch itself may have an issue causing a select shift malfunction. No manual up or down shift available. GO to AUTOMATIC TRANSAXLE/TRANSMISSION EXTERNAL CONTROLS - AISIN AW21/6F35 .
P0961:00 Pressure Control Solenoid A (PCA) PCA  circuit or solenoid failure. PCA  circuit or solenoid failed during operation. Incorrect commanded current detected by TCM  . No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0962:00 PCA  PCA  solenoid signal or grounded circuits either short or open, solenoid circuit failure. Voltage through PCA  is checked. An error will be noted if tolerance is exceeded. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0963:00 PCA  PCA  solenoid short to power circuit failure. Voltage through PCA  is checked. An error will be noted if tolerance is exceeded. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0973:00 Shift Solenoid A (SSA) SSA  solenoid or circuit shorted to ground. Voltage through SSA  (S1) circuit is checked. An error will be noted if tolerance is exceeded. Short to ground failure detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0974:00 SSA  SSA  or circuit shorted to power or open. Voltage through SSA  (S1) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0976:00 Shift Solenoid B (SSB) SSB  solenoid or circuit shorted to ground. Voltage through SSB  (S2) circuit is checked. An error will be noted if tolerance is exceeded. Short to ground failure detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0977:00 SSB  SSB  solenoid or circuit shorted to power or open. Voltage through SSB  solenoid (S2) circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0978:00 Shift Solenoid C (SSC) SSC  circuit or solenoid failure. SSC  circuit or solenoid failed during operation. Incorrect commanded current detected by TCM  . No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0979:00 SSC  SSC  solenoid signal or grounded circuits either shorted or open, solenoid circuit failure. Voltage through SSC  circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0980:00 SSC  SSC  solenoid or circuit shorted to power. Voltage through SSC  circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0981:00 Shift Solenoid D (SSD) SSD  circuit or solenoid failure. SSD  circuit or solenoid failed during operation. Incorrect commanded current detected by TCM  . No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0982:00 SSD  SSD  signal or grounded circuits either shorted or open, solenoid circuit failure. Voltage through SSD  circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0983:00 SSD  SSD  or circuit shorted to power. Voltage through SSD  circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0984:00 Shift Solenoid E (SSE) SSE  circuit or solenoid failure. SSE  circuit or solenoid failed during operation. Incorrect commanded current detected by TCM  . No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0985:00 SSE  SSE  signal or grounded circuits either shorted or open, solenoid circuit failure. Voltage through SSE  circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0986:00 SSE  SSE  or circuit shorted to power. Voltage through SSE  circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0997:00 Shift Solenoid F (SSF) SSF  circuit or solenoid failure. SSF  circuit or solenoid failed during operation. Incorrect commanded current detected by TCM  . No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0998:00 SSF  SSF  signal or grounded circuits either shorted or open, solenoid circuit failure. Voltage through SSF  circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P0999:00 SSF  SSF  or circuit shorted to power. Voltage through SSF  circuit is checked. An error will be noted if tolerance is exceeded. Short to power failure or open circuit detected. No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P1573:00 Accelerator Pedal Position (APP) Sensor APP  sensor input error. PCM has detected an input error from the APP  sensor. No adaptive or self-learning strategy.
NOTE: If this DTC is displayed, a malfunction occurred in the vehicle not the TCM  . Do not install a new TCM  .
REFER to INTRODUCTION - GASOLINE MODELS .
P1576:00 Throttle Position (TP) Sensor TP  sensor input error. TP  not available. Limited function.
NOTE: If this DTC is displayed, a malfunction occurred in the vehicle not the TCM  . Do not install a new TCM  .
REFER to INTRODUCTION - GASOLINE MODELS .
P1657:00 TCM  TCM  communication link error. Controller Area Network (CAN) link error detected by PCM. No engagements, no adaptive or self-learning strategy. Limited fuel and spark. INSTALL a new TCM  .
P1700:00 Transaxle Drive engagement error. TCM  detected neutral in the DRIVE position. No engagements, no adaptive or self-learning strategy. REFER to DIAGNOSIS BY SYMPTOM .
P1701:00 Transaxle Reverse engagement error. TCM  detected neutral in the REVERSE position. No self-learning strategy. REFER to DIAGNOSIS BY SYMPTOM .
P1719:00 PCM Engine torque signal. Torque engine accuracy from PCM inaccurate. Firm shifts and no adaptive learning. PERFORM self-test of PCM. REFER to INTRODUCTION - GASOLINE MODELS to diagnose any DTCs present. If no DTCs, IDENTIFY the driveability symptom present and REFER to INTRODUCTION - GASOLINE MODELS for further diagnosis.
P1919:00 Engine Coolant Temperature (ECT) Sensor signal error. PCM/TCM  have detected an error in the CAN ECT  information. No TCC  engagements, ECT  set to 80°C (176°F).
NOTE: If this DTC is displayed, a malfunction occurred in the vehicle not, the TCM  . Do not install a new TCM  .
REFER to INTRODUCTION - GASOLINE MODELS .
P2757:00 TCC  Solenoid TCC  solenoid circuit failure, stuck OFF. TCC  solenoid circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during On-Board Diagnostic (OBD). No TCC  engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P2758:00 TCC  Solenoid TCC  solenoid circuit failure, stuck ON. TCC  solenoid circuit fails to provide voltage drop across solenoid. Circuit open, shorted or PCM driver failure during OBD  . No TCC  engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P2762:00 TCC  Solenoid TCC  circuit or solenoid failure. TCC  circuit or solenoid failed during operation. Incorrect commanded current detected by TCM  . No engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P2763:00 TCC  Solenoid TCC  circuit shorted to power. TCC  solenoid circuit fails to provide voltage drop across solenoid. Circuit shorted to power. No TCC  engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
P2764:00 TCC  Solenoid TCC  solenoid signal or grounded circuits either short or open solenoid circuit failure. TCC  solenoid circuit fails to provide voltage drop across solenoid. No TCC  engagements, no adaptive or self-learning strategy. Go To PINPOINT TEST A .
U0073:00 TCM CAN  TCM  communication link error. CAN  link error detected by PCM. No engagements, no adaptive or self-learning strategy. REFER to MODULE COMMUNICATIONS NETWORK .
U0100:00 TCM CAN  TCM  communication link error. CAN  link error detected by PCM. No engagements, no adaptive or self-learning strategy.
NOTE: If this DTC is displayed, a malfunction occurred in the vehicle not the TCM  . Do not install a new TCM  .
A module cannot communicate with other modules on the communication network while being reprogrammed. CLEAR any network communication DTCs which may have been set in other modules during reprogramming.CHECK CAN harness between TCM  and other modules. For diagnostic information, REFER to INTRODUCTION - GASOLINE MODELS and REFER to MODULE COMMUNICATIONS NETWORK .