- No communication with the HVAC module -Dual Automatic Temperature Control (DATC) or HVAC module - Electronic Manual Temperature Control (EMTC)
|
- Fuse(s)
- Circuitry open
- HVAC module communication network
|
|
- HVAC functions verification
|
- HVAC system and/or related components
|
|
- The air inlet door is inoperative
|
- Circuitry open/shorted
- Door actuator
- Air inlet door binding or stuck
- HVAC module - EMTC or HVAC module - DATC
|
|
- Incorrect/erratic direction of airflow from outlets
|
- Circuitry open/shorted
- Door actuator
- Mode door binding or stuck
- HVAC module - EMTC or HVAC module - DATC
|
|
|
|
- Circuitry short
- A/C compressor clutch air gap
- A/C cycling switch
- A/C clutch relay
- Blower motor
- Blower motor control
- Blower motor resistor
- Blower motor switch
- PCM
|
|
- Insufficient, erratic or no heat
|
- Low engine coolant level
- Engine overheating
- Plugged or partially plugged heater core
- Temperature blend door is binding or stuck
- Temperature blend door actuator
- Heater hose is kinked or binding
|
|
- The air conditioning (A/C) is inoperative
|
- Fuse(s)
- Circuitry open
- A/C system discharged/low charge
- PCM
- HVAC module - DATC
- HVAC module - EMTC
- A/C clutch relay
- A/C compressor clutch air gap
- A/C pressure transducer
- Evaporator discharge temperature sensor
- A/C clutch field coil
|
|
- The air conditioning (A/C) is always on - A/C compressor does not cycle
|
- Circuitry shorted
- PCM
- A/C clutch relay
- A/C compressor clutch air gap
- A/C pressure transducer
- A/C clutch field coil
|
|
- The air conditioning (A/C) is always on - A/C mode always commanded ON
|
- Circuitry shorted
- PCM
- HVAC module - DATC
- HVAC module - EMTC
- A/C pressure transducer
|
|
- Temperature control is inoperative/does not operate correctly
|
- Circuitry open/shorted
- HVAC module - EMTC
- HVAC module - DATC
- Temperature blend door is binding or stuck
- Temperature blend door actuator
|
|
- The blower motor is inoperative - EMTC
|
- Fuse(s)
- Circuitry open
- A/C blower motor switch
- Blower motor relay
- A/C blower motor
- HVAC module - EMTC
|
|
- The blower motor does not operate correctly - EMTC
|
- Circuitry open/shorted
- A/C blower motor resistor
- A/C blower motor switch
|
|
- The blower motor is inoperative - DATC
|
- Fuse(s)
- Circuitry short/open
- Blower motor relay
- A/C blower motor
- HVAC module - DATC
- A/C blower motor speed control
|
|
- The blower motor does not operate correctly - DATC
|
- Circuitry open/shorted
- A/C blower motor speed control
- HVAC module - DATC
|
|
- The auxiliary blower motor is inoperative
|
- Fuse(s)
- Circuitry open
- Auxiliary blower motor relay 1
- Auxiliary blower motor resistor
- Auxiliary blower motor
- HVAC module - EMTC
- HVAC module - DATC
|
|
- The auxiliary blower motor does not operate correctly
|
- Fuse(s)
- Circuitry open/shorted
- Auxiliary blower motor relay 1
- Auxiliary blower motor relay 2
- Auxiliary blower motor relay 3
- Auxiliary blower motor resistor
- Rear auxiliary control
- HVAC module - EMTC
- HVAC module - DATC
|
- If the auxiliary blower motor does not operate correctly from both the front and rear auxiliary controls, go to Pinpoint Test T .
- If the auxiliary blower motor does not operate correctly from the rear auxiliary controls only, go to Pinpoint Test W .
- If the auxiliary blower motor does not operate correctly from the front auxiliary controls only, CARRY OUT the HVAC Module Cold Boot Process . If the condition returns, INSTALL a new HVAC module. REFER to CLIMATE CONTROL
article. TEST the system for normal operation.
|
- The auxiliary temperature control is inoperative/does not operate correctly using the front/rear auxiliary climate controls
|
- Circuitry open/shorted
- Auxiliary blend door actuator
- HVAC module - EMTC
- HVAC module - DATC
|
- If the auxiliary temperature control is inoperative/does not operate correctly from both the front and rear auxiliary controls, go to Pinpoint Test U .
- If the auxiliary temperature control is inoperative/does not operate correctly from the rear auxiliary controls only, go to Pinpoint Test W .
- If the auxiliary temperature control is inoperative/does not operate correctly from the front auxiliary controls only, CARRY OUT the HVAC Module Cold Boot Process . If the condition returns, INSTALL a new HVAC module. REFER to CLIMATE CONTROL
article. TEST the system for normal operation.
|
- The auxiliary panel/floor control is inoperative/does not operate correctly using the front/rear auxiliary climate controls
|
- Circuitry open/shorted
- Auxiliary mode door actuator
- HVAC module - EMTC
- HVAC module - DATC
|
- If the auxiliary panel/floor control is inoperative/does not operate correctly from both the front and rear auxiliary controls, go to Pinpoint Test V .
- If the auxiliary panel/floor control is inoperative/does not operate correctly from the rear auxiliary controls only, go to Pinpoint Test W .
- If the auxiliary panel/floor control is inoperative/does not operate correctly from the front auxiliary controls only, CARRY OUT the HVAC Module Cold Boot Process . If the condition returns, INSTALL a new HVAC module. REFER to CLIMATE CONTROL
article. TEST the system for normal operation.
|
- The auxiliary temperature, panel/floor and blower motor controls are inoperative/do not operate correctly using the front/rear auxiliary climate controls
|
- Circuitry open/shorted
- Rear auxiliary control
- HVAC module - EMTC
- HVAC module - DATC
|
|
- The temperature set point does not repeat after turning the ignition switch OFF
|
- Fuse
- Circuitry short/open
- HVAC module - DATC
|
- VERIFY Smart Junction Box (SJB) fuse 15 (10A) is OK. If OK, CHECK circuit SBP15 (WH/RD) for a short or open and repair as necessary. If OK, CARRY OUT the HVAC Module Cold Boot Process . If not OK, REFER to the appropriate System Wiring Diagrams article to identify the possible causes of the circuit short. If the condition returns, INSTALL a new HVAC module - DATC.
|
- The temperature display will not switch between Celsius and Fahrenheit
|
- HVAC module - DATC
- Instrument Cluster (IC) module
|
|
- Inaccurate external temperature display
|
- HVAC module - DATC
- Ambient temperature sensor
|
- REFER to description and operation of the HVAC module - DATC external temperature display. If the external temperature display is not operating as described and no DTC is present, CARRY OUT the Temperature Sensor - Ambient component test. If the sensor tests OK, INSTALL a new HVAC module - DATC. REFER to CLIMATE CONTROL
article. TEST the system for normal operation.
|
- A/C pressure relief valve discharging
|
- High system pressure
- A/C pressure relief valve
|
- CHECK the high side system pressure. If the pressure is below the A/C pressure relief valve open pressure, REPLACE the A/C pressure relief valve. If the system pressure is above the A/C pressure relief valve open pressure, REPAIR the system for a restriction.
|