Roof Opening Panel -   The roof opening panel assembly uses an integrated motor and module to operate the roof opening panel. The roof opening panel motor and module are installed new as an assembly. The roof opening panel is an electronically operated glass panel that can be opened, closed or vented by the roof opening panel switch. Actuating the switch in either a forward or rearward motion supplies a ground to the roof opening panel motor/module. The roof opening panel has an express open feature that is activated when the switch is momentarily pressed to the double detent OPEN position. This function is controlled by the roof opening panel motor/module.

The roof opening panel motor must be initialized when repairs are carried out on any part of the roof opening panel system, including: whenever the roof opening panel motor has been removed from the roof opening panel system, the roof opening panel glass has been removed from the roof opening panel system, the roof opening panel assembly has been removed from the vehicle, a new roof opening panel motor has been installed, a new roof opening panel glass has been installed or a new roof opening panel assembly has been installed.