LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2009 >> Flex Limited, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1086 (Windows And Glass) >> Diagnostic Tests >> Glass, Frames and Mechanisms >> Pinpoint Tests >> Pinpoint Test G: A Single Power Window is Inoperative- RH Front, LH or RH Rear, Edge >> Pinpoint Test G: A Single Power Window Is Inoperative - RH Front, LH Or RH Rear, Edge

Pinpoint Test G: A Single Power Window Is Inoperative - RH Front, LH Or RH Rear, Edge

WARNING: This page is about a different car, the 2007 Lincoln MKX and 2007 Ford Edge. However, it is still accessible from the selected car via links, so may be relevant.
  1. G1 CHECK THE VOLTAGE TO THE RH FRONT, LH REAR OR RH REAR WINDOW CONTROL SWITCH 
    • Disconnect: Inoperative Rear Window Control Switch C624 (RH front), C701 (LH rear) or C801 (RH rear)
    • Key in ON position.
    • Fig 1: Measuring Voltage Between The Inoperative Rear Window Connector & Ground
      GF0028368Courtesy of FORD MOTOR CO.
      NOTE: Set the LH front window lock switch to the UNLOCK position.
    • Measure the voltage between the inoperative rear window connector and ground:
      • for the RH front window control switch, measure the voltage between RH front window control switch C624-3, circuit CPW14 (VT/WH), harness side and ground.
      • for the RH rear window control switch, measure the voltage between RH rear window control switch C801-3, circuit CPW14 (VT/WH), harness side and ground.
      • for the LH rear window control switch, measure the voltage between C701-3, circuit CPW14 (VT/WH), harness side and ground.
    • Is the voltage greater than 10 volts? 
    1. YES  : Go to  G3.
    2. NO  : Go to  G2.
  2. G2 CHECK FOR AN OPEN IN CIRCUIT CPW14 (VT/WH) 
    • Disconnect: LH Front Window Control Switch C504B
    • Key in OFF position.
    • Fig 2: Measuring Resistance Between Inoperative Rear Window Connector & LH Front Window Control Switch Connector
      GF0030926Courtesy of FORD MOTOR CO.
    • Measure the resistance between the inoperative rear window connector and the LH front window control switch connector:
      • for the RH front window control switch, measure the resistance between RH front window control switch C624-3, circuit CPW14 (VT/WH), harness side and LH front window control switch C504B-2, circuit CPW14 (VT/WH), harness side.
      • for the RH rear window control switch, measure the resistance between RH rear window control switch C819-3, circuit CPW14 (VT/WH), harness side and LH front window control switch C504B-2, circuit CPW14 (VT/WH), harness side.
      • for the LH rear window control switch, measure the resistance between LH rear window control switch C701-3, circuit CPW14 (VT/WH), harness side and LH front window control switch C504B-2, circuit CPW14 (VT/WH), harness side.
    • Is the resistance less than 5 ohms? 
    1. YES  : INSTALL a new LH front window control switch. REFER to Window Control Switch . TEST the system for normal operation.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  3. G3 CHECK THE GROUNDS TO THE INOPERATIVE REAR WINDOW CONTROL SWITCH 
    • Key in OFF position.
    • Fig 3: Measuring Resistance Between Inoperative Window Control Switch & Ground
      GF0030920Courtesy of FORD MOTOR CO.
    • Measure the resistance between the inoperative window control switch and ground:
      • for the RH front window control switch, measure the resistance between RH front window control switch C624-1, circuit CPW12 (GN/OG), harness side and ground; and between RH front window control switch C624-6, circuit CPW13 (BN/YE), harness side and ground.
      • for the RH rear window control switch, measure the resistance between RH rear window control switch C801-1, circuit CPW17 (BN/GN), harness side and ground; and between RH rear window control switch C801-6, circuit CPW18 (GY/VT), harness side and ground.
      • for the LH rear window control switch, measure the resistance between LH rear window control switch C701-1, circuit CPW15 (YE), harness side and ground; and between LH rear window control switch C701-6, circuit CPW16 (BU/OG), harness side and ground.
    • Are the resistances less than 5 ohms? 
    1. YES  : Go to  G5.
    2. NO  : Go to  G4.
  4. G4 CHECK THE CIRCUITS TO THE INOPERATIVE REAR WINDOW CONTROL SWITCH FOR AN OPEN 
    • Key in OFF position.
    • Disconnect: LH Front Window Control Switch C504A and C504B
    • Fig 4: Measuring Resistance Between LH Front Window Control Switch C504A-3, Circuit CPW12 (GN/OG)
      GF0028380Courtesy of FORD MOTOR CO.
    • For an inoperative RH front power window, measure the resistance between LH front window control switch C504A-3, circuit CPW12 (GN/OG) and RH front window control switch C624-1, circuit CPW12 (GN/OG), harness side; and between LH front window control switch C504A-8, circuit CPW13 (BN/YE) and RH front window control switch C624-6, circuit CPW13 (BN/YE) harness side.
    • Fig 5: Measuring Resistance Between LH Front Window Control Switch C504B-1, Circuit CPW15 (YE)
      GF0030927Courtesy of FORD MOTOR CO.
    • For an inoperative LH rear power window, measure the resistance between LH front window control switch C504B-1, circuit CPW15 (YE) and LH rear window control switch C701-1, circuit CPW15 (YE), harness side; and between LH front window control switch C504B-2, circuit CPW16 (BU/OG) and LH rear window control switch C701-6, circuit CPW16 (BU/OG) harness side.
    • Fig 6: Measuring Resistance Between LH Front Window Control Switch C504B-4, Circuit CPW17 (BN/GN)
      GF0030928Courtesy of FORD MOTOR CO.
    • For an inoperative RH rear power window, measure the resistance between LH front window control switch C504B-4, circuit CPW17 (BN/GN) and RH window control switch C801-1, circuit CPW17 (BN/GN), harness side; and between LH front window control switch C504B-8, circuit CPW18 (GY/VT) and RH rear window control switch C801-6, circuit CPW18 (GY/VT) harness side.
    • Are the resistances less than 5 ohms? 
    1. YES  : INSTALL a new LH front window control switch. REFER to Window Control Switch . TEST the system for normal operation.
    2. NO  : REPAIR the circuit(s) for an open. TEST the system for normal operation.
  5. G5 CHECK THE INOPERATIVE WINDOW CONTROL SWITCH 
    • Key in ON position.
    • For an inoperative RH front window, connect a fused jumper wire between RH front window control switch C624-2, circuit CPW19 (VT), harness side and RH front window control switch C624-3, circuit CPW14 (VT/WH), harness side; and between RH front window control switch C624-5, circuit CPW20 (WH/OG), harness side and RH front window control switch C624-6, circuit CPW13 (BN/YE), harness side. The RH front window should operate in the downward direction.
    • For an inoperative LH rear window, connect a fused jumper wire between LH rear window control switch C701-2, circuit CPW22 (GN/VT), harness side and LH rear window control switch C701-3, circuit CPW14 (VT/WH), harness side; and between LH rear window control switch C701-5, circuit CPW21 (BN), harness side and LH rear window control switch C701-6, circuit CPW16 (BU/OG), harness side. The LH rear window should operate in the downward direction.
    • Fig 7: Connecting Fused Jumper Wire Between RH Rear Window Control Switch C801-2, Circuit CPW23 (GY)
      GF0028375Courtesy of FORD MOTOR CO.
    • For an inoperative RH rear window, connect a fused jumper wire between RH rear window control switch C801-2, circuit CPW23 (GY), harness side and RH rear window control switch C801-3, circuit CPW14 (VT/WH), harness side; and between RH rear window control switch C801-5, circuit CPW24 (WH/VT), harness side and RH rear window control switch C801-6, circuit CPW18 (GY/VT), harness side. The RH rear window should operate in the downward direction.
    • For an inoperative RH front window, connect a fused jumper wire between RH front window control switch C624-2, circuit CPW19 (VT), harness side and RH front window control switch C624-1, circuit CPW12 (GN/OG), harness side; and between RH front window control switch C624-5, circuit CPW20 (WH/OG), harness side and RH front window control switch C624-3, circuit CPW14 (VT/WH), harness side. The RH front window should operate in the upward direction.
    • For an inoperative LH rear window, connect a fused jumper wire between LH rear window control switch C701-2, circuit CPW22 (GN/VT), harness side and LH rear window control switch C701-1, circuit CPW15 (YE), harness side; and between LH rear window control switch C701-5, circuit CPW21 (BN), harness side and LH rear window control switch C701-3, circuit CPW14 (VT/WH), harness side. The LH rear window should operate in the upward direction.
    • Fig 8: Connecting Fused Jumper Wire Between RH Rear Window Control Switch C801-2, Circuit CPW22 (GN/VT)
      GF0028376Courtesy of FORD MOTOR CO.
    • For an inoperative RH rear window, connect a fused jumper wire between RH rear window control switch C801-2, circuit CPW22 (GN/VT), harness side and RH rear window control switch C801-1, circuit CPW17 (BN/GN), harness side; and between RH rear window control switch C801-5, circuit CPW24 (WH/VT), harness side and RH rear window control switch C801-3, circuit CPW14 (VT/WH), harness side. The RH rear window should operate in the upward direction.
    • Did the inoperative window operate correctly? 
    1. YES  : INSTALL a new LH or RH rear window control switch. REFER to Window Control Switch . TEST the system for normal operation.
    2. NO  : Go to  G6.
  6. G6 CHECK THE POWER WINDOW MOTOR CIRCUITS 
    • Key in OFF position.
    • Disconnect: Inoperative Window Motor C608 (RH front), C703 (LH rear) or C828 (RH rear)
    • For an inoperative RH front window, measure the resistance between RH front window control switch C624-2, circuit CPW19 (VT), harness side and RH front window motor C608-2, circuit CPW19 (VT), harness side.
    • Fig 9: Measuring Resistance Between LH Rear Window Control Switch C701-2, Circuit CPW22 (GN/VT)
      GF0030929Courtesy of FORD MOTOR CO.
    • For an inoperative LH rear window, measure the resistance between LH rear window control switch C701-2, circuit CPW22 (GN/VT), harness side and LH rear window motor C703-2, circuit CPW22 (GN/VT), harness side.
    • Fig 10: Measuring Resistance Between RH Rear Window Control Switch C801-2, Circuit CPW23 (GY)
      GF0030930Courtesy of FORD MOTOR CO.
    • For an inoperative RH rear window, measure the resistance between RH rear window control switch C801-2, circuit CPW23 (GY), harness side and RH rear window motor C828-2, circuit CPW23 (GY), harness side.
    • For an inoperative RH front window, measure the resistance between RH front window control switch C624-5, circuit CPW20 (WH/OG), harness side and RH front window motor C608-1, circuit CPW20 (WH/OG), harness side.
    • Fig 11: Measuring Resistance Between LH Rear Window Control Switch C701-5, Circuit CPW21 (BN)
      GF0030931Courtesy of FORD MOTOR CO.
    • For an inoperative LH rear window, measure the resistance between LH rear window control switch C701-5, circuit CPW21 (BN), harness side and LH rear window motor C703-1, circuit CPW21 (BN), harness side.
    • Fig 12: Measuring Resistance Between RH Rear Window Control Switch C801-5, Circuit CPW24 (WH/VT)
      GF0030932Courtesy of FORD MOTOR CO.
    • For an inoperative RH rear window, measure the resistance between RH rear window control switch C801-5, circuit CPW24 (WH/VT), harness side and RH rear window motor C828-1, circuit CPW24 (WH/VT), harness side.
    • Are the resistances less than 5 ohms? 
    1. YES  : INSTALL a new RH front, LH or RH rear window motor. REFER to Window Regulator Motor . TEST the system for normal operation.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.