LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2009 >> Flex Limited, FWD >> Repair and Diagnosis >> Body & Frame >> Windows & Glass - Glass, Frames & Mechanisms >> Diagnosis And Testing >> Glass, Frames and Mechanisms >> Inspection and Verification

Inspection and Verification

  1. Verify the customer concern.
  2. Visually inspect for obvious signs of mechanical or electrical damage.
    VISUAL INSPECTION CHART

    Mechanical Electrical
    • Door window regulator and motor
    • Door glass run
    • Door window glass
    • Loose, corroded connectors
    • Circuitry
    • Window control switch
    • Battery Junction Box (BJB) fuse(s):
      • 20 (40A)
      • 38 (5A)
    • Smart Junction Box (SJB) fuse(s):
      • 1 (30A)
      • 41 (15A)
      • 43 (10A)
    • SJB  circuit breaker 47 (30A)
    • Rear window defrost relay
    • Accessory delay relay
    • Rear window grid
  3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
  4. NOTE: Make sure to use the latest scan tool software release.

    If the cause is not visually evident, connect the scan tool to the Data Link Connector (DLC).

  5. NOTE: The Vehicle Communication Module (VCM) LED prove out confirms power and ground from the DLC  are provided to the VCM  .

    If the scan tool does not communicate with the VCM  :

    • check the VCM  connection to the vehicle.
    • check the scan tool connection to the VCM  .
    • refer to MODULE COMMUNICATIONS NETWORK , No Power To The Scan Tool, to diagnose no power to the scan tool.
  6. If the scan tool does not communicate with the vehicle:
    • verify the ignition key is in the ON position.
    • verify the scan tool operation with a known good vehicle.
    • refer to MODULE COMMUNICATIONS NETWORK to diagnose no response from the SJB  or HVAC module.
  7. Carry out the network test:
    • If the scan tool responds with no communication from one or more modules, refer to MODULE COMMUNICATIONS NETWORK .
    • If the network test passes, retrieve and record the continuous memory DTCs.
  8. Clear the continuous DTCs and carry out the self-test diagnostics for the SJB  and HVAC module.
  9. If the DTCs retrieved are related to the concern, go to the SMART JUNCTION BOX (SJB) DTC CHART  or HVAC MODULE DTC CHART . For all other DTCs, refer to MULTIFUNCTION ELECTRONIC MODULES .
  10. If no DTCs related to the concern are retrieved, GO to SYMPTOM CHART .