Pinpoint Test E: The Roof Opening Panel Does Not Open Or Close
- E1 CHECK THE MOTOR/MODULE FOR INITIALIZATION
- Carry out the roof opening panel motor initialization procedure. Refer to ROOF OPENING PANEL MOTOR INITIALIZATION .
- Is the concern still present?
- Yes : GO to E2.
- No : The system is operating normally at this time. The roof opening panel motor was not initialized.
- E2 CHECK THE POWER WINDOWS
- Ignition ON.
- Verify the power windows operate.
- Do the power windows operate?
- Yes : GO to E3.
- No : REFER to GLASS, FRAMES AND MECHANISMS to diagnose the accessory delay relay circuit.
- E3 CHECK THE ROOF OPENING PANEL SWITCH
- Ignition OFF.
- Disconnect: Roof Opening Panel Switch C912.
- Carry out the Roof Opening Panel Switch Component Test.
Refer to ROOF OPENING PANEL CONTROL SWITCH for component testing.
- Is the roof opening panel switch OK?
- Yes : GO to E4.
- No : INSTALL a new roof opening panel switch. TEST the system for normal operation.
- E4 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR/MODULE - CIRCUITS CBP41 (BU) AND SBP19 (BU/RD)
- Ignition OFF.
- Disconnect: Roof Opening Panel Motor/Module C921.
- Ignition ON.
- Measure the voltage between roof opening panel motor/module C921-3, circuit CBP41 (BU) and C921-6, circuit SBP19 (BU/RD), harness side and ground.
- Are the voltages greater than 10 volts, but less than 16 volts?
- Yes : GO to E5.
- No : VERIFY Smart Junction Box (SJB) fuses 19 (25A) and 41 (15A) are OK. If OK, REPAIR the circuit. If not OK, REFER to POWER TOP/SUNROOF to identify the possible causes of the circuit short. TEST the system for normal operation.
- E5 CHECK THE ROOF OPENING PANEL GROUND - CIRCUIT GD133 (BK)
- Ignition OFF.
- Measure the resistance between roof opening panel motor/module C921-1, circuit GD133 (BK), harness side and ground.
- Is the resistance less than 5 ohms?
- Yes : GO to E6.
- No : REPAIR the circuit. TEST the system for normal operation.
- E6 CHECK CIRCUIT CPR39 (VT/WH) FOR AN OPEN
- Measure the resistance between overhead console C921- 12, circuit CPR39 (VT/WH), and roof opening panel motor/module C921-2, circuit CPR39 (VT/WH) harness side.
- Is the resistance less than 5 ohms?
- Yes : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR39 (VT/WH) between the roof opening panel switch socket and overhead console C921-12. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to E7.
- No : REPAIR the circuit. TEST the system for normal operation.
- E7 CHECK CIRCUIT CPR40 (YE/OG) FOR AN OPEN
- Measure the resistance between overhead console C912-8, circuit CPR40 (YE/OG), and roof opening panel motor/module C921-10, circuit CPR40 (YE/OG) harness side.
- Is the resistance less than 5 ohms?
- Yes : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR40 (YE/OG) between the roof opening panel switch socket and overhead console C912-8. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to E8.
- No : REPAIR the circuit. TEST the system for normal operation.
- E8 CHECK CIRCUIT CPR31 (VT/BN) FOR AN OPEN
- Measure the resistance between overhead console C912-6, circuit CPR31 (VT/BN), and roof opening panel motor/module C921-5, circuit CPR31 (VT/BN) harness side.
- Is the resistance less than 5 ohms?
- Yes : CHECK the overhead console jumper harness for loose pins, an open or a short in circuit CPR31 (VT/BN) between the roof opening panel switch socket and overhead console C912-6. If the overhead console jumper harness is not OK, INSTALL a new overhead console jumper harness, and TEST the system for normal operation. If the overhead console jumper harness is OK, GO to E9.
- No : REPAIR the circuit. TEST the system for normal operation.
- E9 CHECK THE ROOF OPENING PANEL MOTOR/MODULE FOR CORRECT OPERATION
- Disconnect all roof opening panel motor/module connectors.
- Check for:
- corrosion.
- bent pins.
- pushed-out pins.
- Connect all roof opening panel motor/module connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new roof opening panel motor/module. REFER to ROOF OPENING PANEL MOTOR . TEST the system for normal operation.
- No : The system is operating correctly at this time. Concern may have been caused by a loose or corroded connector. TEST the system for normal operation.