LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2009 >> Expedition RWD >> Repair and Diagnosis >> Electrical >> Gauges >> Instrument Cluster Illumination & Instrument Panel Illumination >> Diagnosis And Testing >> Instrument Cluster and Panel Illumination >> Pinpoint Tests >> Pinpoint Test B: All The Hardwired Dimmable Illumination Is Inoperative >> Pinpoint Test B: All The Hardwired DIMMABLE Illumination Is Inoperative

Pinpoint Test B: All The Hardwired DIMMABLE Illumination Is Inoperative

NOTE: Use the correct probe adapter(s) when making measurements. Failure to use the correct probe adapter(s) may damage the connector.
  1. B1 CHECK FOR RECORDED SJB DTCs FROM THE ON-DEMAND SELF-TEST 
    • Ignition OFF.
    • Use the recorded results from the SJB  self-test.
    • Is DTC B2A33 or B29B8 recorded? 
  2. B2 BYPASS THE SJB 
    NOTE: If the jumper wire fails, refer to the SYSTEM WIRING DIAGRAMS - EXPEDITION , SYSTEM WIRING DIAGRAMS - EXPEDITION EL , SYSTEM WIRING DIAGRAMS - NAVIGATOR or SYSTEM WIRING DIAGRAMS - NAVIGATOR L article to identify the possible causes of the circuit short. Run the on-demand self-test (required to clear certain DTCs). Correct any unresolved DTCs. Clear all DTCs. Test the system for normal operation.
    • Disconnect: SJB  C2280b.
    • For DTC B2A32 or DTC B2A33, connect a fused jumper wire between the SJB  C2280b-39, circuit VLN18 (BU/WH) and battery positive.
      Fig 1: Connecting Fused Jumper Wire Between C2280b-39, Circuit VLN18 (BU/WH) And Battery Positive
      G06064792Courtesy of FORD MOTOR CO.
    • For DTC B29B7 or DTC B29B8, connect a fused jumper wire between the SJB  C2280b-52, circuit VLN04 (VT/GY) and battery positive.
      Fig 2: Connecting Fused Jumper Wire Between C2280B-52, Circuit VLN04 (VT/GY) And Battery Positive
      G06133388Courtesy of FORD MOTOR CO.
    • Do(es) the backlighting component(s) illuminate? 
    • Yes:  REMOVE the jumper wire. GO to  B5.
    • No:  For Navigator, if the auxiliary climate control is inoperative, REMOVE the jumper wire. GO to B3  .

      For all others, REMOVE the jumper wire. REPAIR circuit VLN18 (BU/WH) or circuit VLN04 (VT/GY) for an open. CLEAR the DTCs. REPEAT the self-test.

  3. B3 CHECK FOR VOLTAGE TO THE AUXILIARY CLIMATE CONTROL MODULE 
    • Connect: SJB  C2280b.
    • Disconnect: Auxiliary Climate Control Assembly C3198.
    • Place the headlamp switch in the PARKING LAMPS ON position.
    • Rotate the instrument panel dimmer switch to the full illumination position.
    • Measure the voltage between the auxiliary climate control assembly C3198-1, circuit VLN18 (BU/WH), harness side and ground.
      Fig 3: Measuring Voltage Between Auxiliary Climate Control Assembly C3198-1, Circuit VLN18 (BU/WH), Harness Side And Ground
      G06133389Courtesy of FORD MOTOR CO.
    • Is the voltage greater than 10 volts? 
    • Yes:  GO to B4  .
    • No:  REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.
  4. B4 CHECK FOR VOLTAGE TO THE AUXILIARY CLIMATE CONTROL MODULE USING THE CONNECTOR GROUND 
    • Measure the voltage between the auxiliary climate control assembly C3198-3, circuit VLN18 (BU/WH), harness side and the auxiliary climate control assembly C3198-3, circuit GD143 (BK/VT), harness side.
      Fig 4: Measuring Voltage Between Auxiliary Climate Control Assembly C3198-3, Circuit VLN18 (BU/WH) And Auxiliary Climate Control Assembly C3198-3
      G06133390Courtesy of FORD MOTOR CO.
    • Is the voltage greater than 10 volts? 
    • Yes:  INSTALL a new auxiliary climate control assembly. REFER to AUXILIARY CLIMATE CONTROL . CLEAR the DTCs. REPEAT the self-test.

      REPAIR the circuit. CLEAR the DTCs. REPEAT the self-test.

    • No:  REPAIR circuit GD143 (BK/VT) for an open. CLEAR the DTCs. REPEAT the self-test.
  5. B5 CHECK FOR CORRECT SJB OPERATION 
    • Disconnect all the SJB  connectors.
    • Check for:
      • corrosion
      • damaged pins
      • pushed-out pins
    • Connect all the SJB  connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    • Yes:  INSTALL a new SJB  . REFER to MULTIFUNCTION ELECTRONIC MODULES . TEST the system for normal operation.
    • No:  The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector. RUN the on-demand self-test (required to clear certain DTCs). CORRECT any unresolved DTCs. CLEAR all DTCs. TEST the system for normal operation.