Pinpoint Test D: All Power Vent Windows Are Inoperative - Power Vent Windows
- D1 CHECK CIRCUIT 882 (BN/YE) FOR GROUND
- Disconnect: RH Quarter Window Motor C4090
Courtesy of FORD MOTOR CO.
- Measure the resistance between RH quarter window motor C4090-2, circuit 882 (BN/YE), harness side and ground.
- Is the resistance less than 5 ohms?
- YES
: Go to D4.
- NO
: Go to D2.
- D2 CHECK CIRCUIT 882 (BN/YE) FOR AN OPEN
- Disconnect: Quarter Window Switch C2981
Courtesy of FORD MOTOR CO.
- Measure the resistance between RH quarter window motor C4090-2, circuit 882 (BN/YE), harness side and quarter window switch C2981-6, circuit 882 (BN/YE), harness side.
- Is the resistance less than 5 ohms?
- YES
: Go to D3.
- NO
: REPAIR the circuit. TEST the system for normal operation.
- D3 CHECK CIRCUIT 1205 (BK) FOR AN OPEN
Courtesy of FORD MOTOR CO.
- Measure the resistance between RH quarter window switch C2981-8, circuit 1205 (BK), harness side and the ground.
- Is the resistance less than 5 ohms?
- YES
: INSTALL a new quarter window switch. TEST the system for normal operation.
- NO
: REPAIR the circuit. TEST the system for normal operation.
- D4 CHECK CIRCUIT 881 (BN) FOR GROUND
Courtesy of FORD MOTOR CO.
- Measure the resistance between RH quarter window motor C4090-1, circuit 881 (BN), harness side and ground.
- Is the resistance less than 5 ohms?
- YES
: Go to D6.
- NO
: Go to D5.
- D5 CHECK CIRCUIT 881 (BN) FOR AN OPEN
Courtesy of FORD MOTOR CO.
- Measure the resistance between RH quarter window motor C4090-1, circuit 881 (BN), harness side and quarter window switch C2981-7, circuit 881 (BN), harness side.
- Is the resistance less than 5 ohms?
- YES
: INSTALL a new quarter window switch. TEST the system for normal operation.
- NO
: REPAIR the circuit. TEST the system for normal operation.
- D6 CHECK CIRCUIT 194 (PK) FOR VOLTAGE
- Disconnect: Quarter Window Switch C2981
- Key in ON position.
Courtesy of FORD MOTOR CO.
- Measure the voltage between quarter window switch C2981-5, circuit 194 (PK), harness side and ground.
- Is the voltage greater than 10 volts?
- YES
: Go to D7.
- NO
: VERIFY the smart junction box (SJB) fuse 5 (20A) is OK. If OK, REPAIR the circuit. TEST the system for normal operation.
- D7 CHECK CIRCUIT 882 (BN/YE) FOR A SHORT TO GROUND
Courtesy of FORD MOTOR CO.
- Measure the resistance between RH quarter window motor C4090-2, circuit 882 (BN/YE), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- YES
: Go to D8.
- NO
: REPAIR the circuit. TEST the system for normal operation.
- D8 CHECK CIRCUITS 881 (BN) AND 882 (BN/YE) FOR A SHORT TO GROUND
Courtesy of FORD MOTOR CO.
- Measure the resistance between RH quarter window motor C4090-1, circuit 881 (BN), harness side and ground or LH quarter window motor C4048-1, circuit 882 (BN/YE), harness side and ground.
- Is the resistance greater than 10,000 ohms?
- YES
: INSTALL a new quarter window switch. TEST the system for normal operation.
- NO
: REPAIR the circuit. TEST the system for normal operation.