Home >> Ford >> 2007 >> Freestar SEL >> Repair and Diagnosis (Single Page) >> Accessories & Equipment >> Gauges & Instrument Panels >> Instrument Cluster System >> Diagnostic Tests >> Instrument Cluster >> Pinpoint Tests >> Pinpoint Test F: The Tachometer Is Inoperative >> Pinpoint Test F: The Tachometer Is Inoperative

Pinpoint Test F: The Tachometer Is Inoperative

  1. F1 RETRIEVE THE RECORDED DTCs FROM BOTH THE CONTINUOUS AND ON-DEMAND PCM SELF-TESTS 
    • Check for recorded PCM DTCs from the continuous and on-demand self-tests.
    • Are any PCM DTCs recorded? 
    1. YES  : REFER to the Introduction - Gasoline Engines article to continue diagnosis of the DTCs.
    2. NO  : Go to  F2.
  2. F2 CARRY OUT THE INSTRUMENT CLUSTER TACHOMETER GAUGE ACTIVE COMMAND USING THE SCAN TOOL 
    • Key in ON position.
    • Enter the following diagnostic mode on the diagnostic tool: Instrument Cluster Active Command
    • Select the instrument cluster tachometer TACH active command. Scroll the tachometer in 3 segments: 0%, 50% and 100%. Observe the tachometer.
    • Does the tachometer start at 0 rpm, move to about 3,000 rpm and move to 6,000 rpm? 
    1. YES  : Go to  F3.
    2. NO  : Go to  F4.
  3. F3 CHECK FOR CORRECT PCM OPERATION 
    • Disconnect all the PCM connectors.
    • Check for:
      • corrosion
      • damaged pins
      • pushed-out pins
    • Connect all the PCM connectors and make sure they seat correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    1. YES  : INSTALL a new PCM. REFER to ELECTRONIC ENGINE CONTROLS article. TEST the system for normal operation.
    2. NO  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
  4. F4 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION 
    • Disconnect the instrument cluster connector.
    • Check for:
      • corrosion
      • damaged pins
      • pushed-out pins
    • Connect the instrument cluster connector and make sure it seats correctly.
    • Operate the system and verify the concern is still present.
    • Is the concern still present? 
    1. YES  : INSTALL a new instrument cluster. REFER to Instrument Cluster . TEST the system for normal operation.
    2. NO  : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.