Removal and Installation

  1. With the vehicle in NEUTRAL, position it on a hoist. For additional information, refer to JACKING AND LIFTING .
  2. Recover the refrigerant. For additional information, refer to CLIMATE CONTROL SYSTEM-GENERAL INFORMATION AND DIAGNOSIS .
  3. Remove the lower radiator air deflector.
  4. Disconnect the compressor manifold and tube assembly at the suction accumulator.
    • Discard the O-ring seal.
    • To install, tighten to 8 Nm (71 lb-in).
      Fig 1: Locating Compressor Manifold And Tube Assembly At Accumulator
      G04653902Courtesy of FORD MOTOR CO.
  5. Remove the suction accumulator bracket nut.
    • To install, tighten to 7 Nm (62 lb-in).
      Fig 2: Locating Suction Accumulator Bracket Nut
      G04653903Courtesy of FORD MOTOR CO.
  6. Remove the 2 suction accumulator bracket bolts.
    • To install, tighten to 7 Nm (62 lb-in).
      Fig 3: Locating Suction Accumulator Bracket Bolts
      G04653904Courtesy of FORD MOTOR CO.
  7. Disconnect the evaporator outlet line fitting at the suction accumulator.
    • Discard the O-ring seals.
      Fig 4: Locating Evaporator Outlet Line Fitting
      G04653905Courtesy of FORD MOTOR CO.
  8. Remove the suction accumulator.
  9. To install, reverse the removal procedure.
  10. Evacuate, leak test and charge the refrigerant system. For additional information, refer to CLIMATE CONTROL SYSTEM-GENERAL INFORMATION AND DIAGNOSIS .