Manifold Gauge Set Connection
SPECIAL TOOL(S)
| R-134a Manifold Gauge Set 176-R032A or equivalent |
- Turn both valves on the R-134a Manifold Gauge Set clockwise to close the low- and high-pressure hoses to the center manifold and center hose.
- Remove the A/C charging valve cap from the low-pressure service gauge port valve.
- Remove the A/C charging valve cap from the high-pressure service gauge port valve.
- Connect the R-134a Manifold Gauge Set low-pressure hose and the R-134a low side quick disconnect to the low-pressure service gauge port valve.
- Connect the R-134a Manifold Gauge Set high-pressure hose and the R-134a high side quick disconnect to the high-pressure service gauge port valve.
NOTE:
The low-pressure service gauge port valve is located on the suction accumulator and can be accessed from below the RH side of the front bumper cover.
NOTE:
The high-pressure service gauge port valve is located on the A/C condenser and can be accessed through an opening in the LH top of the radiator grille opening panel reinforcement.