LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2006 >> Focus ZX5 SE, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 993 (Sunroof) >> Diagnostic Tests >> Roof Opening Panel >> Pinpoint Tests >> Pinpoint Test E: The Roof Opening Panel Does Not Open or Close >> Pinpoint Test E: The Roof Opening Panel Does Not Open Or Close

Pinpoint Test E: The Roof Opening Panel Does Not Open Or Close

WARNING: This page is about a different car, the 2008 Mercury Mariner and 2008 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
  1. E1 CHECK CIRCUIT (DB) FOR POWER 
    • Key in OFF position.
    • Disconnect: Roof Opening Panel Module Connector
    • Key in ON position.
    • Measure the voltage between the roof opening panel module connector, pin 6, circuit (DB), harness side and ground.
    • Fig 1: Checking Circuit For Voltage
      GF0023879Courtesy of FORD MOTOR CO.
    • Is the voltage greater than 10 volts? 
    1. YES  : Go to  E2.
    2. NO  : VERIFY the smart junction box (SJB) circuit breaker 47 (30A) is OK. If OK, REPAIR the circuit. TEST the system for normal operation. If not OK, REFER to the Wiring Diagrams Manual to identify the possible causes of the circuit short. TEST the system for normal operation.
  2. E2 CHECK CIRCUIT (BK) FOR AN OPEN 
    • Key in OFF position.
    • Measure the resistance between the roof opening panel module connector, pin 4, circuit (BK), harness side and ground.
    • Fig 2: Checking Circuit For Open
      GF0023880Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : Go to  E3.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  3. E3 CHECK POWER TO THE ROOF OPENING PANEL MOTOR - CIRCUIT (OG) 
    • Connect: Roof Opening Panel Module Connector
    • Disconnect: Roof Opening Panel Motor Connector
    • Key in ON position.
    • While pressing the roof opening panel switch to the OPEN position, measure the voltage between the roof opening panel motor connector, pin 3, circuit (OG), harness side and ground.
    • Fig 3: Checking Circuit For Voltage
      GF0023881Courtesy of FORD MOTOR CO.
    • Is the voltage greater than 10 volts? 
    1. YES  : Go to  E6.
    2. NO  : Go to  E4.
  4. E4 CHECK CIRCUIT (OG) FOR AN OPEN 
    • Key in OFF position.
    • Disconnect: Roof Opening Panel Module Connector
    • Measure the resistance between the roof opening panel motor connector, pin 3, circuit (OG), harness side and the roof opening panel module connector, pin 8, circuit (OG), harness side.
    • Fig 4: Checking Circuit For Open
      GF0023882Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : Go to  E5.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  5. E5 CHECK CIRCUIT (OG) FOR A SHORT TO GROUND 
    • Measure the resistance between the roof opening panel motor connector, pin 3, circuit (OG), harness side and ground.
    • Fig 5: Checking Circuit For Ground
      GF0023883Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms? 
    1. YES  : Go to  E9.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  6. E6 CHECK VOLTAGE TO THE ROOF OPENING PANEL MOTOR - CIRCUIT (RD) 
    • While pressing the roof opening panel switch to the CLOSED position, measure the voltage between the roof opening panel motor connector, pin 1, circuit (RD), harness side and ground.
    • Fig 6: Checking Circuit For Voltage
      GF0023884Courtesy of FORD MOTOR CO.
    • Is the voltage greater than 10 volts? 
    1. YES  : INSTALL a new roof opening panel motor. REFER to Roof Opening Panel Motor . TEST the system for normal operation.
    2. NO  : Go to  E7.
  7. E7 CHECK CIRCUIT (RD) FOR AN OPEN 
    • Key in OFF position.
    • Disconnect: Roof Opening Panel Module Connector
    • Measure the resistance between the roof opening panel module connector, pin 7, circuit (RD), harness side and the roof opening panel motor connector, pin 1, circuit (RD), harness side.
    • Fig 7: Checking Circuit For Open
      GF0023885Courtesy of FORD MOTOR CO.
    • Is the resistance less than 5 ohms? 
    1. YES  : Go to  E8.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  8. E8 CHECK CIRCUIT (RD) FOR A SHORT TO GROUND 
    • Measure the resistance between the roof opening panel motor connector, pin 1, circuit (RD), harness side and ground.
    • Fig 8: Checking Circuit For Short To Ground
      GF0023886Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms? 
    1. YES  : Go to  E9.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.
  9. E9 CHECK THE ROOF OPENING PANEL SWITCH 
    • Disconnect: Roof Opening Panel Switch Connector
    • Carry out the roof opening panel control switch component test. Refer to appropriate COMPONENT TESTING article.
    • Did the roof opening panel control switch pass the component test?  
    1. YES  : Go to  E10.
    2. NO  : INSTALL a new roof opening panel switch. TEST the system for normal operation.
  10. E10 CHECK CIRCUIT (VT) FOR AN OPEN OR SHORT TO GROUND 
    • Disconnect: Roof Opening Panel Module Connector
    • Connect: Roof Opening Panel Switch Connector
    • Measure the resistance between the roof opening panel module connector, pin 3, circuit (VT), harness side and ground with the roof opening panel control switch at rest, and then while pressing the roof opening panel switch to the CLOSE position.
    • Fig 9: Checking Circuit For Open
      GF0023888Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms with the switch at rest, and less than 5 ohms with the switch in the CLOSE position? 
    1. YES  : Go to  E11.
    2. NO  : REPAIR the circuit. TEST the system for normal operation
  11. E11 CHECK CIRCUIT (WH) FOR AN OPEN OR SHORT TO GROUND 
    • Measure the resistance between the roof opening panel module connector, pin 2, circuit (WH), harness side and ground with the roof opening panel control switch at rest, and then while pressing the roof opening panel switch to the OPEN position.
    • Fig 10: Checking Circuit For Open
      GF0023889Courtesy of FORD MOTOR CO.
    • Is the resistance greater than 10,000 ohms with the switch at rest, and less than 5 ohms with the switch in the OPEN position? 
    1. YES  : INSTALL a new roof opening panel module. REFER to Roof Opening Panel Module . TEST the system for normal operation.
    2. NO  : REPAIR the circuit. TEST the system for normal operation.