GENERAL SPECIFICATIONS

Item Specification
A/C Compressor 
A/C compressor type DKS-17DS
Rotation Clockwise
A/C Compressor Magnetic Clutch 
Air gap between pulley and hub 0.3-0.6 mm
(0.012-0.024 in)
A/C Low charge Protection Switch - 2.3L, 3.0L (4V) 
Close 110-165 kPa (16-24 psi)
Open 62-76 kPa (9-11 psi)
A/C Pressure Relief Valve 
Open 3,682 kPa (534 psi) minimum
Dual-Function Pressure Switch 
High speed fan ON (closed contacts) 1,965-2,172 kPa
(285-315 psi)
High speed fan OFF (open contacts) 1,482-1,965 kPa
(30-70 psi)
A/C clutch cut-in (closed contacts) 1,517-1,931 kPa
(220-280 psi)
A/C clutch cut-out (open contacts) 2,999-3,275 kPa
(435-475 psi)
Front Thermistor 
Cut-in/cut-out 2.2°C (36°F)/0.6°C (33°F)
NOTE: The specifications apply to non-hybrid vehicles only. For hybrid specifications, refer to CLIMATE CONTROL SYSTEM - GENERAL INFORMATION AND DIAGNOSTICS - HYBRID article.