P0491 - Secondary Air Injection (Air) System Insufficient Flow (Bank 1)

WARNING: This page does not describe the selected car, but rather 32 other vehicles, including the 2008 Mercury Sable, 2008 Mercury Mountaineer, 2008 Mercury Milan, 2008 Mercury Mariner, and 2008 Mercury Grand Marquis. However, it is still accessible from the selected car via links, so may be relevant.
P0491 - SECONDARY AIR INJECTION (AIR) SYSTEM INSUFFICIENT FLOW (BANK 1)

Description:  The AIR system detected that there was insufficient mass air flow change during pump switching (ON/OFF).
Possible Causes: 
  • Secondary AIR pump with no or low air flow.
  • Secondary AIR bypass solenoid leaking/blocked or stuck open/closed.
  • Secondary AIR diverter valve leaking/blocked or stuck open/closed.
  • Secondary AIR air hose restricted.
  • Secondary AIR vacuum hoes restricted or leaking.
Diagnostic Aids:  Measured air flow is less than expected. Visually inspect the secondary AIR inlet hose.
Application  Key On Engine Off  Key On Engine Running  Continuous Memory 
All   - refer to PINPOINT TEST HM . refer to PINPOINT TEST HM .