Home >> Ford >> 2006 >> Focus ZX5 SE, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 585 (Glass, Frames And Mechanisms) >> Diagnosis And Testing >> Glass, Frames and Mechanisms >> Pinpoint Tests >> Pinpoint Test E: A Single Power Window Is Inoperative, RH Front - Zephyr >> Normal Operation

Normal Operation

WARNING: This page is about a different car, the 2006 Mercury Milan, 2006 Lincoln Zephyr, and 2006 Ford Fusion. However, it is still accessible from the selected car via links, so may be relevant.

Under normal operation, the LH and RH front power window control switches receive power from the delay accessory relay through circuit CBP02 (GN). The RH window motor receives battery power through circuit SBB35 (BU/RD) at all times and ground through circuit GD139 (BK/YE). When the LH or RH front window control switch is operated in the UP position, the RH front window motor receives a voltage signal through circuit CPW13 (BN/YE). When the LH or RH front window control switch is operated in the DOWN position, the RH front window motor receives a voltage signal through circuit CPW12 (GN/OG). When the RH front window motor receives a ground signal on circuit CPW31 (GN/WH), the RH front window motor will enter one-touch up/down mode.