Pinpoint Test T: The Check Fuel Cap Warning Indicator Is Never/Always On: Testing
WARNING: This page is about a different car, the 2005 Mercury Montego, 2005 Ford Freestyle, and 2005 Ford Five Hundred. However, it is still accessible from the selected car via links, so may be relevant.
- T1 RETRIEVE THE RECORDED POWERTRAIN CONTROL MODULE (PCM) DTCs FROM BOTH CONTINUOUS AND ON-DEMAND SELF-TESTS
- Check for recorded PCM DTCs from the continuous and on-demand self-tests.
- Are any PCM DTCs recorded?
- Yes : REFER to the INTRODUCTION - GASOLINE article to continue diagnosis of the DTCs.
- No : GO to T2.
- T2 CARRY OUT THE INSTRUMENT CLUSTER WARNING LAMPS AND CHIME ACTIVE COMMAND USING THE DIAGNOSTIC TOOL
- Key in ON position.
- Enter the following diagnostic mode on the scan tool: Instrument Cluster Active Command.
- Select the instrument cluster warning lamps and chime active command. Trigger the all lamps active command on and off. Observe the check fuel cap indicator.
- Does the check fuel cap indicator illuminate when triggered on and turn off when triggered off?
- Yes : GO to T4.
- No : GO to T3.
- T3 CHECK FOR CORRECT INSTRUMENT CLUSTER OPERATION
- Disconnect the instrument cluster connector.
- Check for:
- corrosion
- pushed-out pins
- Connect the instrument cluster connector and make sure it seats correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new instrument cluster. REFER to INSTRUMENT CLUSTER . TEST the system for normal operation.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.
- T4 CHECK FOR CORRECT PCM OPERATION
- Disconnect all the PCM connectors.
- Check for:
- corrosion
- pushed-out pins
- Connect all the PCM connectors and make sure they seat correctly.
- Operate the system and verify the concern is still present.
- Is the concern still present?
- Yes : INSTALL a new PCM. REFER to ELECTRONIC ENGINE CONTROLS . TEST the system for normal operation.
- No : The system is operating correctly at this time. The concern may have been caused by a loose or corroded connector.