LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2006 >> Focus ZX5 SE, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1408 (HVAC - Climate Control System - General Information And Diagnostics) >> General Procedures >> Refrigerant Oil Adding >> Oil Injection Using a Dye/Lubricant Injector

Oil Injection Using a Dye/Lubricant Injector

WARNING: This page is about a different car, the 2010 Lincoln Town Car. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: If fluorescent leak detection dye is also to be added during A/C charging, the dye may be added to the dye/lubricant injector, from the R-134a Loop/Add On Injector Kit-Set, along with the PAG oil.
  1. Evacuate the refrigerant system. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging .
  2. Assemble the dye/lubricant injector and the correct adapters from the R-134a Loop/Add On Injector Kit-Set to match the amount of refrigerant compressor oil to be injected.
  3. Verify that all the valves on the dye/lubricant injector are closed.
  4. Fig 1: Verifying All Valves On Dye/Lubricant Injector Are Closed
    GF0041085Courtesy of FORD MOTOR CO.
  5. Fill the dye/lubricant injector with the correct amount of clean, new PAG oil.
  6. Fig 2: Filling Fluorescent Dye Injector Reservoir With 7 ml (0.25 oz.) Of Fluorescent Dye
    GF0041086Courtesy of FORD MOTOR CO.
  7. Install the dye/lubricant injector between the low-side service gauge port valve and the refrigerant service station or manifold gauge set.
  8. Open all valves and charge the refrigerant system. For additional information, refer to Air Conditioning (A/C) System Recovery, Evacuation and Charging .