LEMON Manuals: Even more car manuals for everyone
Home >> Ford >> 2006 >> Focus ZX5 SE, Standard >> Repair and Diagnosis >> External Pages >> Different car >> Section 1311 (Sunroof - Roof Opening Panel) >> Diagnosis And Testing >> Roof Opening Panel >> Inspection and Verification

Inspection and Verification

WARNING: This page is about a different car, the 2010 Mercury Mariner and 2010 Ford Escape. However, it is still accessible from the selected car via links, so may be relevant.
  1. Verify the customer concern.
  2. Visually inspect for obvious signs of mechanical and electrical damage.
    VISUAL INSPECTION CHART

    Mechanical Electrical
    • Roof opening panel control switch
    • Roof opening panel motor
    • Roof opening panel glass
    • Roof opening panel shield
    • Roof opening panel drain hoses
    • Lifting arm
    • Roof opening panel drain trough
    • Smart Junction Box (SJB) fuse(s):
      • 4 (30A)
      • 41 (15A)
    • Accessory delay relay
    • Roof opening panel switch
    • Roof opening panel motor
  3. If an obvious cause for an observed or reported concern is found, correct the cause (if possible) before proceeding to the next step.
  4. If the cause is not visually evident, GO to SYMPTOM CHART - ROOF OPENING PANEL  or GO to SYMPTOM CHART - NVH .