DTC P1244: Alternator Load High Input
P1244 - ALTERNATOR LOAD HIGH INPUT
| Description: | The powertrain control module (PCM) monitors generator load from the generator/regulator in the form of frequency. The concern indicates the input is higher than the load should be in normal operation. The load input could be high when a battery short to ground exists. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | Verify the battery voltage is 14.5 volts. Verify the generator/regulator has the correct part number. |
||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test HY . | ||