DTC P0400: Exhaust Gas RECIRCULATION (EGR) Flow
P0400 - EXHAUST GAS RECIRCULATION (EGR) FLOW
| Description: | The electric EGR (EEGR) system is monitored once per drive cycle during steady state conditions above 77 km/h (48 mph). The test fails when a concern is detected by powertrain control module (PCM) calculations indicating the EGR flow is less or greater than expected. | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | All of the following sensors input data to the PCM for correct operation of the EEGR system: engine coolant temperature (ECT), crankshaft position (CKP), intake air temperature (IAT), MAF, throttle position (TP), MAP. Any DTC relating to these sensors must be resolved prior to addressing code P0400. | ||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test KD . | ||