DTC P0350: Ignition Coil Primary/Secondary Circuit
P0350 - IGNITION COIL PRIMARY/SECONDARY CIRCUIT
| Description: | Each ignition primary circuit is continuously monitored. The test fails when the powertrain control module (PCM) does not receive a valid ignition diagnostic monitor (IDM) pulse signal from the ignition module (integrated in the PCM). | ||
| Possible Causes: |
|
||
| Diagnostic Aids: | Use the 12-volt non-powered test lamp to verify START/RUN voltage at the ignition coil harness connector. Check the coil driver circuit for open, short to VPWR, or short to ground. |
||
| Application | Key On Engine Off | Key On Engine Running | Continuous Memory |
| All | GO to Pinpoint Test JE . | ||