Instrument Cluster Dealer Test Mode
NOTE:
The table below uses XXX's to represent a numeric or alpha-numeric value. The value may display the same amount of characters represented by the XXX's or there may be more/less depending on the type of display. For example: F XXX may display F 125.
INSTRUMENT CLUSTER DEALER TEST MODE
| Instrument Cluster Odometer Display | Description |
|---|---|
| GAGE | Carries out a gauge sweep of all gauges and then displays the present value. |
| All segments illuminated | Carries out a prove-out of all trip/ODO segments. |
| LEDs | Illuminates all micro-controlled LEDs. |
| R XXXX FAIL | Returns to normal operation of all-micro controlled LEDs and displays hexadecimal ROM level and type. |
| NRXXX | Displays the hexadecimal ROM level and type. |
| EE XX FAIL | Displays the hexadecimal EE levels. |
| DTXX | Displays the hexadecimal coding of the start date. |
| HRXXXX | Displays the hexadecimal coding of the final manufacturing test hours. |
| CF1 XX | Displays the hexadecimal coding of the 1st byte of the module configuration settings. |
| DTC XXXX | Displays the stored DTCs in hexadecimal format. DTCs displayed are those detected in continuous operation, not during the self-test. |
| EXXXX | Displays the speed signal input in miles per hour (mph). |
| XXXX | Displays the speed signal input in km/h. |
| SGXXXX | Displays the speedometer driver gauge counts in decimal format. |
| TXXXX | Displays the tachometer value. |
| TGXXXX | Displays the hexadecimal value (000-400 decimal 1-1024) for the tachometer gauge driver counts. |
| FXXX | Displays the present fuel level ratio in decimal format. A short circuit is displayed 000-009, normal is displayed 010-254, an open circuit is displayed 255. |
| FPXXX | Displays the present filtered fuel level percent status from the sender in decimal format. Normal range is 000-254; 255 indicates an open or short was detected. |
| FGXXXX | Displays the fuel gauge driver counts in decimal format. |
| XXX C | Displays the last engine coolant temperature gauge input value. Dashes indicates that the message is invalid. |
| CGXXXX | Displays the last temperature gauge driver counts in decimal. |
| ODOXXX | Displays the odometer input received through the CAN in decimal value as a rolling count. |
| BATXXX | Displays the present SBATT (battery voltage) input in decimal (00.0-19.6 volts). |
| BF-X | Displays the brake fluid input. Good fluid level (open) displayed as -O and low brake fluid level (ground) displayed as -G. |
| HB -X | Displays the parking brake input. Parking brake released (open) displayed as -O and parking brake applied (ground) displayed as -G. |
| LCXXX | Displays the LCD illumination duty cycle. Percent of PWM duty cycle in 1.0 steps GND = 0% and Vbatt = 100%. |
| CR-X | CRANK detect circuit check. High input is displayed as -b and low input is displayed as -O. |
| P0-XX | Displays the 8-bit hexadecimal value of Port 0 readings. |
| P3-XX | Displays the 8-bit hexadecimal value of Port 3 readings. |
| P9-XX | Displays the 8-bit hexadecimal value of Port 9 readings. |
| AN0-XXX | Displays the 8-bit hexadecimal value of the A/D Port 00. |
| AN1-XXX | Displays the 8-bit hexadecimal value of the A/D Port 01. |
| AN2-XXX | Displays the 8-bit hexadecimal value of the A/D Port 02. |
| AN3-XXX | Displays the 8-bit hexadecimal value of the A/D Port 03. |
| AN4-XXX | Displays the 8-bit hexadecimal value of the A/D Port 04. |